Description
M-2100+ Digital Clamp Meter for AC Current, AC/DC Voltage and Resistance
The MULTImic M-2100+ Digital Clamp Meter is a multifunctional measuring instrument designed for AC current measurement up to 2000 A. It features a wide, teardrop-shaped 55 mm diameter clamp opening for measuring high AC currents. The meter also supports AC/DC voltage and resistance measurements, diode testing, and continuity checks. Its data hold and automatic power-off functions provide added convenience for electrical testing and maintenance applications.
Accuracy Specifications
| Function | Range | Accuracy | Maximum Input / Protection |
|---|---|---|---|
| AC Current (50/60 Hz), Manual Ranging | 20 A | ±1.2% rdg ± 10 dgt | AC 2000 A (within 3 seconds) |
| 200 A | ±1.2% rdg ± 10 dgt | ||
| 2000 A | ±1.2% rdg ± 8 dgt | ||
| AC Voltage (50/60 Hz) / DC Voltage, Auto Ranging | 2 V | ±0.7% rdg ± 5 dgt | DC 750 V or AC 750 V RMS |
| 20 V | ±1.2% rdg ± 5 dgt | ||
| 200 V | ±1.2% rdg ± 5 dgt | ||
| 750 V | ±1.2% rdg ± 5 dgt | ||
| Resistance (Ω), Auto Ranging | 200 Ω | ±1.2% rdg ± 5 dgt | Input protection: 250 V RMS (within 10 seconds) |
| 2 kΩ | ±1.2% rdg ± 5 dgt | ||
| 20 kΩ | ±1.2% rdg ± 5 dgt | ||
| 200 kΩ | ±1.2% rdg ± 5 dgt | ||
| 2000 kΩ | ±1.2% rdg ± 5 dgt | ||
| 20 MΩ | ±3.0% rdg ± 10 dgt | ||
| Continuity Check | 200 Ω | Beeper sounds below approximately 50 Ω | 250 V RMS |
| Diode Test | 2 V | ±10% rdg ± 3 dgt | 250 V RMS |
Key Features of M-2100+ Digital Clamp Meter
- AC current measurement with 20 A, 200 A, and 2000 A ranges
- Wide 55 mm diameter teardrop-shaped clamp opening
- AC voltage measurement
- DC voltage measurement
- Resistance measurement
- Diode test function
- Continuity check function
- Data hold function for retaining measurement readings
- Automatic power-off function
- Conforms to IEC safety requirements, as specified by the manufacturer
Additional Information
Withstanding Voltage: |
AC 3700V 1 minute max. (Between the core of CT and outer case) |
Storage Temperature: |
-10℃ to 60℃, 70%RH max. ( Without condensation ) |
Accuracy: |
See accuracy specifications in description tab |
Power supply: |
1.5V (AM-4, LR03 or AAA)×2 |
Power consumption: |
3.5mW |
Safety standard: |
IEC 61010-1, IEC 61010-2-032 Installation CategoryⅡ600V or CategoryⅢ300V. |
Jaw opening capability: |
55mmφ |
Size: |
85(W)×240(H)×34(D)mm |
Accessories: |
Hard carrying case | Instruction manual | Test lead | Batteries Accuracy |
Display: |
3.5 digit LCD, max. reading of 1999 |
Over range indication: |
Blanking of all digits except MSD 1 |
Data hold indication: |
"DH" mark on LCD |
Low battery indication: |
"Battery" mark on LCD |
Auto power off: |
Automatically turned off if the meter has not been used for approx. 10 minutes. |
E.M.C. standard: |
EN 61326 |
Measuring method: |
Dual slope integration mode |
Battery life: |
Approx. 500 hours continuous |
Sampling: |
2 times/sec |