Description
M-2010+ Digital Clamp Meter for AC Current, AC/DC Voltage and Resistance
The MULTImic M-2010+ Digital Clamp Meter is a multifunctional measuring instrument designed for AC current measurement with 20 A, 200 A and 1000 A ranges. Featuring a 40 mm diameter clamp opening, it also supports AC/DC voltage and resistance measurements, diode testing and continuity checks. The data hold and automatic power-off functions provide added convenience for electrical testing and maintenance.
Accuracy Specifications
Conditions: 23°C ± 5°C, 80% RH or less.
| Function | Range | Accuracy | Maximum Input / Protection |
|---|---|---|---|
| AC Current (50/60 Hz) | 20 A | ±1.2% rdg ± 10 dgt | AC 1000 A |
| AC Current (50/60 Hz) | 200 A | ±1.2% rdg ± 10 dgt | AC 1000 A |
| AC Current (50/60 Hz) | 1000 A | ±1.0% rdg ± 8 dgt | AC 1000 A |
| AC Voltage (50/60 Hz) | 2 V | ±0.7% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| AC Voltage (50/60 Hz) | 20 V | ±1.2% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| AC Voltage (50/60 Hz) | 200 V | ±1.2% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| AC Voltage (50/60 Hz) | 1000 V | ±1.2% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| DC Voltage | 2 V | ±0.7% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| DC Voltage | 20 V | ±1.2% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| DC Voltage | 200 V | ±1.2% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| DC Voltage | 1000 V | ±1.2% rdg ± 5 dgt | DC 1000 V or AC 1000 V RMS |
| Resistance | 200 Ω | ±1.2% rdg ± 5 dgt | 250 V RMS input protection (30 seconds) |
| Resistance | 2 kΩ | ±1.2% rdg ± 5 dgt | 250 V RMS input protection (30 seconds) |
| Resistance | 20 kΩ | ±1.2% rdg ± 5 dgt | 250 V RMS input protection (30 seconds) |
| Resistance | 200 kΩ | ±1.2% rdg ± 5 dgt | 250 V RMS input protection (30 seconds) |
| Resistance | 2000 kΩ | ±1.2% rdg ± 5 dgt | 250 V RMS input protection (30 seconds) |
| Resistance | 20 MΩ | ±3.0% rdg ± 10 dgt | 250 V RMS input protection (30 seconds) |
| Continuity Check | 2 kΩ | Beeper sounds below approximately 300 Ω | 250 V RMS |
| Diode Test | 2 V | ±10% rdg ± 3 dgt | 250 V RMS |
Key Features of M-2010+ Digital Clamp Meter
- AC current measurement with 20 A, 200 A and 1000 A ranges
- 40 mm diameter clamp opening
- AC/DC voltage measurement
- Resistance measurement
- Diode test function
- Continuity check function
- Data hold function for retaining measurement readings
- Automatic power-off function
- Conforms to IEC safety requirements, as specified by the manufacturer
Additional Information
Withstanding Voltage: |
AC 5500V 1 minute max. (Between the core of CT and outer case) |
Storage Temperature: |
-10℃ to 60℃, 70%RH max. ( Without condensation ) |
Accuracy: |
See accuracy specifications in description tab |
Power supply: |
1.5V (AM-4, LR03 or AAA)×2 |
Power consumption: |
3.5mW |
Safety standard: |
IEC 61010-1, IEC 61010-2-032 | Installation Category IV-600V phase to earth |
Jaw opening capability: |
40mmφ |
Size: |
70(W)×223(H)×34(D)mm |
Accessories: |
Hard carrying case:1 | Instruction manual:1 Test | lead:1set | Batteries:2 |
Display: |
3.5 digit LCD, max. reading of 1999 |
Over range indication: |
Blanking of all digits except MSD 1 |
Data hold indication: |
"DH" mark on LCD |
Low battery indication: |
"Battery" mark on LCD |
Auto power off: |
Approx. 10 minutes later after power on |
E.M.C. standard: |
EN 61326 |
Measuring method: |
Dual slope integration mode |
Battery life: |
Approx. 500 hours continuous |
Sampling: |
2 times/sec |