M-2002 2CT Method Mini Clamp Tester

The MULTI M-2002 2CT Method Mini Clamp Tester is a portable True RMS instrument designed to measure AC leakage current in single-phase electrical systems. Its two-CT measurement method enables leakage current testing in distribution panels where the line (L) and neutral (N) conductors are separated, making it difficult to clamp both conductors together with a conventional leakage current clamp meter.

The M-2002 combines a 40 mm main CT with a 5 mm auxiliary CT (CTP-05-2) to support two-CT leakage current measurement. It also provides conventional AC leakage and load current measurement through the main CT, with a maximum load current measurement range of 200 A. Its compact design, LCD display, and data hold function support practical field measurements.

Measuring Functions and Ranges

Measuring Function Measuring Range
AC Leakage Current (By 2CT) 0 ~ 200mA/2000mA (Leakage current)
AC Leakage Current (By Main CT)
AC Load Current 0 ~ 20mA/200A (Load current)

Accuracy Specifications

Conditions: 23°C ± 5°C, less than 85% RH. Accuracy at 50/60 Hz.

Function Range Resolution Accuracy
2CT AC 1000mA 0.1mA ±1% rdg ± 10dgt
AC 10A 0.001A ±1% rdg ± 10dgt
Main CT AC 20A 0.01A ±1% rdg ± 10dgt
AC 200A 0.1A 0 ~ 100A: ±1% rdg ± 10dgt
101 ~ 150A: ±3% rdg ± 10dgt
151 ~ 200A: ±6% rdg ± 10dgt

Key Features of M-2002 2CT Method Mini Clamp Tester

  • 2CT Leakage Current Measurement: Measures AC leakage current in single-phase systems where the line and neutral conductors cannot be clamped together.
  • True RMS Measurement: Provides True RMS readings for AC leakage and load current.
  • Dual CT Configuration: Features a 40 mm main CT and a 5 mm auxiliary CT (CTP-05-2).
  • AC Current Measurement: Supports AC load current measurement up to 200 A.
  • Compact Field Design: Lightweight, approximately 190 g, with LCD display, data hold, and automatic power-off.

Documents

Catalog: e_ca_m2002.pdf

Instruction Manual: e-ma-m2002.pdf

Application Examples:e_ex_m2002.jpg

View AllClose

Additional Information

Measuring function:
see the table in description tab
Measuring ranges:
see the table in description tab
Accuracy:
See accuracy specifications in description tab
Display:
LCD max. 9999 count with annunciators
Power supply:
1.5V (AM-4, LR03 or AAA)×2
Power consumption:
36mW
Safety standard:
IEC 61010-1, IEC 61010-2-032 Installation CategoryⅢ 1500V phase to earth.
Jaw opening capability:
55mmφ
Size:
85(W)×240(H)×34(D)mm
Accessories:
Hard carrying case:1 | Instruction manual:1 | Test lead:1set | Batteries:2
Display:
3.5 digit LCD, max. reading of 3999
AC conversion:
True rms responding
A/D conversion:
Dual slope integration method
Jaw opening capability:
40mm φ (Main CT) || 5mm φ (Auxiliary CT)
Over range indication:
Over range indication
Data hold indication:
"DH" mark on LCD
Low battery indication:
"B" mark on LCD
Auto power off:
Approx. 10 minutes after power on
Sampling rate:
2 time/sec.
Limitation of circuit voltage:
Less than AC/DC 500V
Withstanding voltage:
AC 2000V/1 minute between CT and outer case
Operating temperature:
0 ~ 40 ℃ , < 85%RH (without condensation)
Storage temperature:
-10 ~ 60 ℃ < 70%RH (without condensation)
Power supply:
LR03,AM-4 or AAA size Alkaline battery×3
Size:
64(W)×195(H)×24(D)mm(Main CT) || 25(W)×114(H)×19(D)mm(Auxiliary CT)
Accessories:
Carrying case:1 Instruction manual:1 Batteries:3 Auxiliary CT (CTP-05-2) with 1.5m lead cable:1