Description
M-200 Universal Clamp Tester
The M-200 Universal Clamp Tester is a compact AC current measuring instrument featuring two measurement methods: a conventional 33 mm clamp CT and a U-type CT. The 33 mm clamp provides 20 A and 200 A measurement ranges, while the U-type CT measures AC current up to 200 A without separating the conductors in supported cable configurations.
The U-type CT is designed for measuring load current in single-phase IV cables, parallel VVF cables, and three-phase VVR cables, with an approximate accuracy of ±5%. The instrument also features a 3.5-digit LCD, data-hold function, and a compact 170 × 54 × 21 mm body.
33mmφCT Accuracy Specifications
Conditions: 23℃±5℃, 80% RH or less. Accuracy at 50/60Hz.
| Range | Resolution | Accuracy |
|---|---|---|
| AC 20A | 10mA | ±1.2% rdg ± 5 dgt |
| AC 200A | 100mA | ±1.2% rdg ± 5 dgt |
U Type CT Accuracy Specifications
Range: AC 200A. Maximum conductor size: 20mmφ.
Conditions: 23℃±5℃, 80% RH or less. Accuracy at 50/60Hz.
| Cable Type | Resolution | Accuracy |
|---|---|---|
| Single phase IV cable | 0.1A | Approx. ±5% |
| Parallel VVF cable | 0.1A | Approx. ±5% |
| Three phase VVR cable | 0.1A | Approximate value |
Key Features of M-200 Universal Clamp Tester
- Dual CT Measurement: Features a 33 mm clamp CT and U-type CT for AC current measurement.
- AC Current Ranges: 20 A and 200 A ranges with the clamp CT; up to 200 A with the U-type CT.
- U-Type CT Measurement: Measures load current in single-phase IV, parallel VVF, and three-phase VVR cables without separating the conductors.
- Measurement Accuracy: ±1.2% of reading ±5 digits for the clamp CT at 50/60 Hz; approximately ±5% for the specified U-type CT cable configurations.
- Compact Design with Data Hold: 3.5-digit LCD, data-hold function, and lightweight body weighing approximately 100 g.
Documents
Instruction Manual: e-ma-m200.pdf
Additional Information
Measuring method: |
Dual slope integration mode |
Measuring ranges: |
AC 30 A/300 A |
Accuracy: |
See accuracy specifications in description tab |
Display: |
3.5 digit LCD, max. reading of 1999 |
Jaw opening capability: |
φ33mm |
Over range indication: |
Blanking of all digits except MSD 1 |
Data hold indication: |
"DH" mark on LCD |
Low battery indication: |
"B" mark on LCD |
Sampling rate: |
2 time/sec. |
Withstanding voltage: |
AC 2200V 1 minute max. (Between the core of CT and outer case) |
Storage temperature: |
0~40℃, < 80%RH (without condensation) |
Power supply: |
1.5V(LR-44 or SR-44) battery×2 |
Size: |
54(W)×170(H)×21(D)mm |
Accessories: |
Soft case:1 || Instruction manual:1 || Batteries LR-44(1.55V):2 |
Power consumption: |
2.5mW |
Battery life: |
SR-44 (200 hours), LR-44 (100 hours) |