Description

HCL-3000D High Insulation Digital Clamp Tester

The HCL-3000D High Insulation Digital Clamp Tester is designed to measure AC load current in high-voltage circuits operating from 80 to 7000 Vrms. It provides two manually selectable measurement ranges, 2000 mA and 20 A, at 50/60 Hz.

The instrument features a 35 mm jaw opening and a push-to-open, pull-to-disconnect mechanism. Its high-insulation construction includes a specified insulation resistance of at least 100 MΩ and a dielectric withstand rating of AC 15 kV for one minute between the operating handle and CT core.

Accuracy Specifications

Accuracy conditions: 23℃±5℃, 80%RH or less (50/60Hz)

Function Range Resolution Accuracy
AC Current (ACA) 2000 mA 1 mA ±2% rdg ±8 dgt
20 A 0.01 A ±2% rdg ±8 dgt

Key Features of HCL-3000D High Insulation Digital Clamp Tester

  • High-Voltage Circuit Measurement: Designed for AC current measurement in circuits operating from 80 to 7000 Vrms.
  • Dual AC Current Ranges: Manually selectable 2000 mA and 20 A ranges at 50/60 Hz.
  • Measurement Accuracy: ±2% of reading ±8 digits for both current ranges.
  • 35 mm Jaw Opening: Push-to-open and pull-to-disconnect mechanism for clamp operation.
  • High Insulation Performance: Minimum 100 MΩ insulation resistance and AC 15 kV withstand voltage for one minute between the operating handle and CT core.

Documents

Catalog: e_ca_hcl-3000d.pdf

Instruction Manual: e_ma_hcl3000d.pdf

View AllClose

Additional Information

Measuring function:
AC load current
Jaw opening capability:
φ35mm
Measuring ranges:
AC 0~2000mA/20A (50Hz/60Hz), 2 ranges manual
Accuracy:
check the description tab
Limitation of circuit voltage:
AC 80Vrms to 7000Vrms
Withstanding voltage:
AC 15kV, 1 minute (Between operation handle and core of CT)
Insulation Resistance:
100MΩ or more by DC 1000V insulation tester (Between operation handle and core of CT)
Operating temperature:
0~40℃, less than 80%RH without condensation
Power supply:
AAA size battery×2
Dimension:
70(W)×356(H)×32(D)mm
Accessories:
Carrying case:1 Instruction manual:1 Batteries:2