MCL-3000D Digital Clamp Tester with Big CT Window (CE)

The MCL-3000D Digital Clamp Tester is a True RMS AC current measuring instrument featuring a large 108 × 128 mm CT window and a measurement range of up to 3000 A. Its large clamp opening allows current measurement around conductors without disconnecting the circuit.

The tester provides three manually selectable AC current ranges of 30 A, 300 A, and 3000 A, with a 3200-count LCD display and data hold function. It operates at 50/60 Hz and is specified to IEC 61010-1 and IEC 61010-2-032, with a CAT III 600 V safety rating.

AC Current Accuracy Specifications

Conditions: 23℃±5℃, 80%RH or less. Frequency: 50/60Hz.

Range Resolution Accuracy
AC 30A 0.01A ±1.5% rdg ± 8 dgt
AC 300A 0.1A ±1.5% rdg ± 8 dgt
AC 3000A 1A ±2.0% rdg ± 8 dgt

Key Features of MCL-3000D Digital Clamp Tester with Big CT Window (CE)

  • Large CT Window: 108 × 128 mm opening with a maximum jaw opening of 108 mm for AC current measurement without disconnecting the conductor.
  • AC Current Measurement up to 3000 A: Three manually selectable ranges of 30 A, 300 A, and 3000 A.
  • True RMS Measurement: AC-coupled True RMS response at 50/60 Hz.
  • Measurement Accuracy: ±1.5% rdg ±8 dgt for 30 A and 300 A ranges; ±2.0% rdg ±8 dgt for the 3000 A range.
  • Electrical Safety Rating: IEC 61010-1 and IEC 61010-2-032, CAT III 600 V, as specified by the manufacturer.

Documents

Catalog : e_ca_mcl-3000d.pdf

Instruction Manual: e-ma-mcl3000d.pdf

View AllClose

Additional Information

Measuring method:
Dual slope integration mode
Measuring ranges:
AC30A/300A/3000A (50/60Hz) 3 ranges manual
Accuracy:
See accuracy specifications in description tab
Display:
LCD, max. 3200 count with annunciators
Jaw opening capability:
108mm (108x128mm)
Over range indication:
"OL" mark on LCD
Data hold indication:
"DH" mark on LCD
Low battery indication:
"B" mark on LCD
Sampling rate:
2 time/sec.
Measuring function:
AC load current
Operating temperature:
0℃ - 40℃, less than 80%RH (Without condensation)
Storage temperature:
-10℃ - 60℃, less than 70%RH (Without condensation)
Power supply:
1.5V battery[UM-4 or AAA size]x 2
Size:
194(W) x 341.5(H) x 52(D) mm
Accessories:
Battery (UM-4):2 || Instruction Manual:1 || Carrying Case:1 || Hand Strap:1
AC Conversion:
AC coupled true rms responding
Safety standard:
IEC61010-1, IEC61010-2-032 Installation Category. CategoryⅢ600V
Power consumption:
Approx. 6mW
Limitation of circuit voltage:
Less than AC 600V
Withstanding Voltage:
AC 5500V, 1 minute (between operation handle and core of CT)
Battery life:
Approx. 200 hours continuous
Auto power off function:
The meter is set to power off Approx. 10 minute later after power on.