  • ifm Flow Sensor SA5000
  • ifm Flow Sensor SA5000
  • ifm Flow Sensor SA5000
  • ifm Flow Sensor SA5000

Description

ifm Flow Sensor SA5000

Introduction – ifm Flow Sensor SA5000

The ifm Flow Sensor SA5000 is a robust and intelligent calorimetric flow sensor designed for simultaneous measurement of flow rate and temperature in industrial process media. Engineered for precision and reliability, it operates efficiently with water, air, glycol solutions, and oils—making it ideal for a wide range of automation and fluid control systems. Its integrated red/green display allows operators to instantly identify process conditions, ensuring safe and efficient system monitoring.

Built for harsh industrial environments, the SA5000 offers a durable stainless-steel housing and IP67 protection, guaranteeing long-term stability under high pressure (up to 100 bar) and variable temperature conditions. The sensor features both analog and digital outputs, along with IO-Link communication, providing flexibility and ease of integration with modern control systems.

With its rotatable process connection, gold-plated electrical contacts, and scalable 4–20 mA output, the ifm Flow Sensor SA5000 ensures optimal alignment, reliable connection, and smooth commissioning. Configuration can be done directly via buttons or remotely through IO-Link, offering maximum convenience for operators and maintenance teams.

Distributed in the UAE and across the MENA region by Dubai Sensor, this advanced flow sensor combines German engineering quality with smart connectivity, making it a preferred solution for precise flow and temperature monitoring in modern automation systems.

Key Features & Benefits

  • Simultaneous flow and temperature measurement

  • Calorimetric measuring principle for reliable performance in liquids and gases

  • Optimized for water, oils, air, and glycol media

  • IO-Link communication for digital data exchange and remote configuration

  • Red/green display for clear visualization of flow range and process status

  • 2 switching outputs + 1 analog (4–20 mA) output for flexible signal options

  • Rotatable housing (345°) for easy installation alignment

  • Gold-plated contacts ensure durable and stable electrical connection

  • Robust stainless-steel housing (316L) for long service life

  • High pressure resistance (up to 100 bar) and IP65/IP67 protection

  • Teach function and user-friendly interface for quick parameterization

  • Maintenance-free design with long MTTF of 132 years

Technical Specifications – ifm Flow Sensor SA5000

Parameter

Specification

Model

SA5000 (SAD10XDBFRKG/US-100)

Measuring principle

Calorimetric

Media types

Water, glycol solutions, oils, air

Flow range (liquids – relative mode)

0.04...6 m/s

Flow range (gases – relative mode)

2...200 m/s

Medium temperature range

-20...90 °C

Pressure rating

100 bar (10 MPa)

Accuracy (relative mode)

±(7 % MW + 2 % MEW)

Repeatability

0.05 m/s (water)

Response time

0.5 s (water); 1.8 s (oil); 7 s (air)

Analogue output

4–20 mA (scalable)

Digital outputs

2 × PNP/NPN configurable

Signal types

Switching, analogue, frequency, IO-Link

Operating voltage

18–30 V DC

Protection rating

IP65 / IP67

Ambient temperature

-40...80 °C

Housing material

Stainless steel 316L / PBT-GF30

Process connection

M18 × 1.5 internal thread

Display

4-digit alphanumeric, red/green

Weight

257 g

Electrical connection

M12 connector, gold-plated contacts

Standards / EMC

DIN EN 60947-5-9

UL Approval

E174189

MTTF

132 years

Standards & Certifications

  • UL approval: UL File No. E174189 (I003)

  • EMC compliance: DIN EN 60947-5-9

  • Shock resistance: 50 g (11 ms, DIN EN 60068-2-27)

  • Vibration resistance: 20 g (10–2000 Hz, DIN EN 60068-2-6)

  • Protection classes: IP65 / IP67

  • MTTF: 132 years for long-term reliability

Applications & Industries

The ifm Flow Sensor SA5000 is suitable for diverse process and automation applications including:

  • Cooling water and hydraulic oil flow monitoring

  • Air and compressed gas systems

  • Machine tool lubrication circuits

  • Process control in food, beverage, and chemical plants

  • HVAC systems and energy management installations

  • General fluid control in industrial automation across the UAE and MENA region

Installation, Commissioning & Maintenance

Installation is simple thanks to the rotatable process connection (M18×1.5) and clear display alignment. The SA5000 can be directly mounted in pipelines or tanks for continuous flow and temperature monitoring. Configuration is accessible through the three-button interface or via IO-Link communication for remote parameter setup.

Maintenance requirements are minimal due to its solid-state sensing principle, robust stainless-steel construction, and self-monitoring electronics. Regular calibration is generally unnecessary under normal conditions, reducing downtime and total cost of ownership.

Why Choose ifm Flow Sensor SA5000

Engineered with precision German technology, the ifm Flow Sensor SA5000 offers unmatched reliability and intelligent monitoring for industrial fluid systems. Its combination of analog and digital outputs, robust design, and intuitive operation make it an ideal choice for both OEM integration and process optimization.

With proven durability and superior performance under high-pressure, high-temperature, and dynamic conditions, this sensor provides outstanding long-term stability. As an officially distributed product by Dubai Sensor, the SA5000 ensures local technical support and availability across the UAE and MENA markets.

Ordering Guide

  1. Model: SA5000 (SAD10XDBFRKG/US-100)

  2. Supply Voltage: 18–30 V DC

  3. Output Options: 2 × switching outputs (PNP/NPN) + 1 × analogue (4–20 mA) + IO-Link

  4. Process Connection: M18×1.5 internal thread

  5. Accessories: M12 connectors, mounting clamps, and IO-Link configuration tools (optional)

For authorized sourcing and technical assistance, contact Dubai Sensor, the official distributor of ifm Flow Sensor SA5000 in the UAE and MENA region.

FAQ – ifm Flow Sensor SA5000

Q1: What type of measuring principle does the ifm Flow Sensor SA5000 use?
A1: The SA5000 operates on the calorimetric measuring principle, detecting flow rate by measuring heat transfer in moving media such as water, air, or oil.

Q2: Can the SA5000 measure both flow and temperature?
A2: Yes. The sensor measures flow velocity and medium temperature simultaneously, providing two process values in one compact device.

Q3: What output options are available on the SA5000?
A3: It includes two digital outputs, one scalable 4–20 mA analog output, and IO-Link communication for advanced data exchange and remote parameterization.

Q4: What media are suitable for this flow sensor?
A4: The SA5000 is optimized for water, glycol solutions, air, and oils (both low- and high-viscosity types).

Q5: What is the maximum pressure rating of the SA5000?
A5: It can operate safely under pressures up to 100 bar (10 MPa).

Q6: How accurate is the SA5000 in flow measurement?
A6: In relative mode, it provides an accuracy of ±(7 % MW + 2 % MEW), with repeatability of 0.05 m/s for water in the 0.05–3 m/s range.

Q7: Does the SA5000 have IO-Link functionality?
A7: Yes. It supports IO-Link (COM2, 38.4 kBaud, Revision 1.1) for easy integration, diagnostics, and configuration according to IEC 61131-9 standards.

Q8: What protection ratings does the SA5000 have?
A8: The device features IP65 and IP67 protection, ensuring dust-tightness and resistance to water immersion, making it suitable for harsh industrial environments.

Q9: Is the SA5000 approved for use under UL standards?
A9: Yes. It has UL approval (File No. E174189, No. I003) and meets relevant EMC standards (DIN EN 60947-5-9).

Documents

Manual

View AllClose

Warranty Information

One Year Warranty
View AllClose

Additional Information

Number of inputs and outputs:
Number of digital outputs: 2; Number of analog outputs: 1
Process connection:
threaded connection M18 x 1,5 Internal thread
System:
gold-plated contacts
Media:
water; glycol solutions; air; oils
Note on media:
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C) | high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature[°C]:
-20...90
Pressure rating:
100 bar | 10 MPa
MAWP (for applications according to CRN)[bar]:
100
Operating voltage[V]:
18...30 DC
Current consumption[mA]:
< 100
Protection class:
III
Reverse polarity protection:
yes
Power-on delay time[s]:
10
Measuring principle:
calorimetric
Total number of outputs:
2
Output signal:
switching signal; analog signal; frequency signal; IO-Link; (configurable)
Electrical design:
PNP/NPN
Number of digital outputs:
2
Output function:
normally open / closed; (configurable)
Max. voltage drop switching output DC[V]:
2.5
Permanent current rating of switching output DC[mA]:
250
Number of analog outputs:
1
Analog current output[mA]:
4...20; (scalable)
Max. load[Ω]:
350
Short-circuit protection:
yes
Type of short-circuit protection:
yes (non-latching)
Overload protection:
yes
Frequency of the output[Hz]:
0...1000
Probe length L[mm]:
45
Operating mode:
relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative)
Temperature monitoring | Measuring range[°C]:
-20...90
Temperature monitoring | Resolution[°C]:
0.2
Liquid media - absolute operating mode | Setting range[m/s]:
0.04...3
Liquid media - absolute operating mode | Greatest sensitivity[m/s]:
0.04...3
Liquid media - relative operating mode | Setting range[m/s]:
0.04...6
Liquid media - relative operating mode | Greatest sensitivity[m/s]:
0.04...3
Gases - operating mode "absolute" | Setting range[m/s]:
2...100
Gases - operating mode "absolute" | Greatest sensitivity[m/s]:
30...100
Gases - operating mode "relative" | Setting range[m/s]:
2...200
Gases - operating mode "relative" | Greatest sensitivity[m/s]:
30...100
Temperature drift[cm/s x 1/K]:
0,003 m/s x 1/K (< 20 °C; > 70 °C)
Max. temperature gradient of medium[K/min]:
100
Absolute operating mode | Repeatability:
0,05 m/s; (water; Flow velocity: 0,05...3 m/s)
Relative operating mode | Accuracy:
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448)
Relative operating mode | Repeatability:
0,05 m/s; (water; Flow velocity: 0,05...3 m/s)
Temperature monitoring | Temperature drift:
± 0,005 K/°C
Temperature monitoring | Accuracy[K]:
± 0,3 / ± 1; (water; Flow velocity: 0,3...3 m/s / air; Flow velocity: > 10 m/s)
Response time[s]:
0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring | Dynamic response T05 / T09[s]:
1,5 (T09); (water; Flow velocity: 0,3...3 m/s)
Parameter setting options:
hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color
Communication interface:
IO-Link
Transmission type:
COM2 (38,4 kBaud)
IO-Link revision:
1.1
SDCI standard:
IEC 61131-9
Profiles:
Smart Sensor - SSP 0(Generic Profiled Sensor) | Function(Device identification) | Function(Process data variable) | Function(Device diagnosis)
SIO mode:
yes
Required master port class:
A
Process data analog:
2
Process data binary:
2
Min. process cycle time[ms]:
3
Supported DeviceIDs:
Factory setting / ModE = (REL) - DeviceID: 533 | ModE = (GAS) - DeviceID:547 | ModE = (LIQU) - DeviceID: 540
Ambient temperature[°C]:
-40...80
Storage temperature[°C]:
-40...100
Protection:
IP 65; IP 67
EMC:
DIN EN 60947-5-9
Shock resistance:
DIN EN 60068-2-27(50 g (11 ms))
Vibration resistance:
DIN EN 60068-2-6(20 g (10...2000 Hz))
MTTF[years]:
132
UL approval:
UL approval number(I003) | File number UL(E174189)
Weight[g]:
257
Housing:
tubular
Dimensions[mm]:
Ø 34 / L = 142
Material:
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts):
stainless steel (1.4404 / 316L); Gasket: FKM
Probe diameter[mm]:
8
Installation length EL[mm]:
45
Display:
Display unit(6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)) | Switching status(2 x LED, yellow) | Measured values(alphanumeric display, red/green 4-digit)
Remarks:
MW = Measured value | MEW = Final value of the measuring range
Pack quantity:
1 pcs.
Connection:
Connector: 1 x M12; coding: A; Contacts: gold-plated