The ifm Flow Sensor SA5000 is a robust and intelligent calorimetric flow sensor designed for simultaneous measurement of flow rate and temperature in industrial process media. Engineered for precision and reliability, it operates efficiently with water, air, glycol solutions, and oils—making it ideal for a wide range of automation and fluid control systems. Its integrated red/green display allows operators to instantly identify process conditions, ensuring safe and efficient system monitoring.
Built for harsh industrial environments, the SA5000 offers a durable stainless-steel housing and IP67 protection, guaranteeing long-term stability under high pressure (up to 100 bar) and variable temperature conditions. The sensor features both analog and digital outputs, along with IO-Link communication, providing flexibility and ease of integration with modern control systems.
With its rotatable process connection, gold-plated electrical contacts, and scalable 4–20 mA output, the ifm Flow Sensor SA5000 ensures optimal alignment, reliable connection, and smooth commissioning. Configuration can be done directly via buttons or remotely through IO-Link, offering maximum convenience for operators and maintenance teams.
Distributed in the UAE and across the MENA region by Dubai Sensor, this advanced flow sensor combines German engineering quality with smart connectivity, making it a preferred solution for precise flow and temperature monitoring in modern automation systems.
Key Features & Benefits
- Simultaneous flow and temperature measurement
- Calorimetric measuring principle for reliable performance in liquids and gases
- Optimized for water, oils, air, and glycol media
- IO-Link communication for digital data exchange and remote configuration
- Red/green display for clear visualization of flow range and process status
- 2 switching outputs + 1 analog (4–20 mA) output for flexible signal options
- Rotatable housing (345°) for easy installation alignment
- Gold-plated contacts ensure durable and stable electrical connection
- Robust stainless-steel housing (316L) for long service life
- High pressure resistance (up to 100 bar) and IP65/IP67 protection
- Teach function and user-friendly interface for quick parameterization
- Maintenance-free design with long MTTF of 132 years
Technical Specifications – ifm Flow Sensor SA5000
|
Parameter |
Specification |
|
Model |
SA5000 (SAD10XDBFRKG/US-100) |
|
Measuring principle |
Calorimetric |
|
Media types |
Water, glycol solutions, oils, air |
|
Flow range (liquids – relative mode) |
0.04...6 m/s |
|
Flow range (gases – relative mode) |
2...200 m/s |
|
Medium temperature range |
-20...90 °C |
|
Pressure rating |
100 bar (10 MPa) |
|
Accuracy (relative mode) |
±(7 % MW + 2 % MEW) |
|
Repeatability |
0.05 m/s (water) |
|
Response time |
0.5 s (water); 1.8 s (oil); 7 s (air) |
|
Analogue output |
4–20 mA (scalable) |
|
Digital outputs |
2 × PNP/NPN configurable |
|
Signal types |
Switching, analogue, frequency, IO-Link |
|
Operating voltage |
18–30 V DC |
|
Protection rating |
IP65 / IP67 |
|
Ambient temperature |
-40...80 °C |
|
Housing material |
Stainless steel 316L / PBT-GF30 |
|
Process connection |
M18 × 1.5 internal thread |
|
Display |
4-digit alphanumeric, red/green |
|
Weight |
257 g |
|
Electrical connection |
M12 connector, gold-plated contacts |
|
Standards / EMC |
DIN EN 60947-5-9 |
|
UL Approval |
E174189 |
|
MTTF |
132 years |
Standards & Certifications
- UL approval: UL File No. E174189 (I003)
- EMC compliance: DIN EN 60947-5-9
- Shock resistance: 50 g (11 ms, DIN EN 60068-2-27)
- Vibration resistance: 20 g (10–2000 Hz, DIN EN 60068-2-6)
- Protection classes: IP65 / IP67
- MTTF: 132 years for long-term reliability
Applications & Industries
The ifm Flow Sensor SA5000 is suitable for diverse process and automation applications including:
- Cooling water and hydraulic oil flow monitoring
- Air and compressed gas systems
- Machine tool lubrication circuits
- Process control in food, beverage, and chemical plants
- HVAC systems and energy management installations
- General fluid control in industrial automation across the UAE and MENA region
Installation, Commissioning & Maintenance
Installation is simple thanks to the rotatable process connection (M18×1.5) and clear display alignment. The SA5000 can be directly mounted in pipelines or tanks for continuous flow and temperature monitoring. Configuration is accessible through the three-button interface or via IO-Link communication for remote parameter setup.
Maintenance requirements are minimal due to its solid-state sensing principle, robust stainless-steel construction, and self-monitoring electronics. Regular calibration is generally unnecessary under normal conditions, reducing downtime and total cost of ownership.
Why Choose ifm Flow Sensor SA5000
Engineered with precision German technology, the ifm Flow Sensor SA5000 offers unmatched reliability and intelligent monitoring for industrial fluid systems. Its combination of analog and digital outputs, robust design, and intuitive operation make it an ideal choice for both OEM integration and process optimization.
With proven durability and superior performance under high-pressure, high-temperature, and dynamic conditions, this sensor provides outstanding long-term stability. As an officially distributed product by Dubai Sensor, the SA5000 ensures local technical support and availability across the UAE and MENA markets.
Ordering Guide
- Model: SA5000 (SAD10XDBFRKG/US-100)
- Supply Voltage: 18–30 V DC
- Output Options: 2 × switching outputs (PNP/NPN) + 1 × analogue (4–20 mA) + IO-Link
- Process Connection: M18×1.5 internal thread
- Accessories: M12 connectors, mounting clamps, and IO-Link configuration tools (optional)
For authorized sourcing and technical assistance, contact Dubai Sensor, the official distributor of ifm Flow Sensor SA5000 in the UAE and MENA region.
FAQ – ifm Flow Sensor SA5000
Q1: What type of measuring principle does the ifm Flow Sensor SA5000 use?
A1: The SA5000 operates on the calorimetric measuring principle, detecting flow rate by measuring heat transfer in moving media such as water, air, or oil.
Q2: Can the SA5000 measure both flow and temperature?
A2: Yes. The sensor measures flow velocity and medium temperature simultaneously, providing two process values in one compact device.
Q3: What output options are available on the SA5000?
A3: It includes two digital outputs, one scalable 4–20 mA analog output, and IO-Link communication for advanced data exchange and remote parameterization.
Q4: What media are suitable for this flow sensor?
A4: The SA5000 is optimized for water, glycol solutions, air, and oils (both low- and high-viscosity types).
Q5: What is the maximum pressure rating of the SA5000?
A5: It can operate safely under pressures up to 100 bar (10 MPa).
Q6: How accurate is the SA5000 in flow measurement?
A6: In relative mode, it provides an accuracy of ±(7 % MW + 2 % MEW), with repeatability of 0.05 m/s for water in the 0.05–3 m/s range.
Q7: Does the SA5000 have IO-Link functionality?
A7: Yes. It supports IO-Link (COM2, 38.4 kBaud, Revision 1.1) for easy integration, diagnostics, and configuration according to IEC 61131-9 standards.
Q8: What protection ratings does the SA5000 have?
A8: The device features IP65 and IP67 protection, ensuring dust-tightness and resistance to water immersion, making it suitable for harsh industrial environments.
Q9: Is the SA5000 approved for use under UL standards?
A9: Yes. It has UL approval (File No. E174189, No. I003) and meets relevant EMC standards (DIN EN 60947-5-9).
Documents
Additional Information
Number of inputs and outputs: |
Number of digital outputs: 2; Number of analog outputs: 1 |
Process connection: |
threaded connection M18 x 1,5 Internal thread |
System: |
gold-plated contacts |
Media: |
water; glycol solutions; air; oils |
Note on media: |
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C) | high-viscosity oils with viscosity: > 40 mm²/s (40 °C) |
Medium temperature[°C]: |
-20...90 |
Pressure rating: |
100 bar | 10 MPa |
MAWP (for applications according to CRN)[bar]: |
100 |
Current consumption[mA]: |
< 100 |
Protection class: |
III |
Reverse polarity protection: |
yes |
Power-on delay time[s]: |
10 |
Measuring principle: |
calorimetric |
Total number of outputs: |
2 |
Output signal: |
switching signal; analog signal; frequency signal; IO-Link; (configurable) |
Electrical design: |
PNP/NPN |
Number of digital outputs: |
2 |
Output function: |
normally open / closed; (configurable) |
Max. voltage drop switching output DC[V]: |
2.5 |
Permanent current rating of switching output DC[mA]: |
250 |
Number of analog outputs: |
1 |
Analog current output[mA]: |
4...20; (scalable) |
Max. load[Ω]: |
350 |
Short-circuit protection: |
yes |
Type of short-circuit protection: |
yes (non-latching) |
Overload protection: |
yes |
Frequency of the output[Hz]: |
0...1000 |
Probe length L[mm]: |
45 |
Temperature monitoring | Measuring range[°C]: |
-20...90 |
Temperature monitoring | Resolution[°C]: |
0.2 |
Temperature drift[cm/s x 1/K]: |
0,003 m/s x 1/K (< 20 °C; > 70 °C) |
Max. temperature gradient of medium[K/min]: |
100 |
Temperature monitoring | Temperature drift: |
± 0,005 K/°C |
Temperature monitoring | Accuracy[K]: |
± 0,3 / ± 1; (water; Flow velocity: 0,3...3 m/s / air; Flow velocity: > 10 m/s) |
Response time[s]: |
0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
Temperature monitoring | Dynamic response T05 / T09[s]: |
1,5 (T09); (water; Flow velocity: 0,3...3 m/s) |
Parameter setting options: |
hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color |
Communication interface: |
IO-Link |
Transmission type: |
COM2 (38,4 kBaud) |
IO-Link revision: |
1.1 |
SDCI standard: |
IEC 61131-9 |
Profiles: |
Smart Sensor - SSP 0(Generic Profiled Sensor) | Function(Device identification) | Function(Process data variable) | Function(Device diagnosis) |
SIO mode: |
yes |
Required master port class: |
A |
Process data analog: |
2 |
Process data binary: |
2 |
Min. process cycle time[ms]: |
3 |
Supported DeviceIDs: |
Factory setting / ModE = (REL) - DeviceID: 533 | ModE = (GAS) - DeviceID:547 | ModE = (LIQU) - DeviceID: 540 |
Ambient temperature[°C]: |
-40...80 |
Storage temperature[°C]: |
-40...100 |
Protection: |
IP 65; IP 67 |
EMC: |
DIN EN 60947-5-9 |
Shock resistance: |
DIN EN 60068-2-27(50 g (11 ms)) |
Vibration resistance: |
DIN EN 60068-2-6(20 g (10...2000 Hz)) |
MTTF[years]: |
132 |
UL approval: |
UL approval number(I003) | File number UL(E174189) |
Weight[g]: |
257 |
Housing: |
tubular |
Dimensions[mm]: |
Ø 34 / L = 142 |
Material: |
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 |
Materials (wetted parts): |
stainless steel (1.4404 / 316L); Gasket: FKM |
Probe diameter[mm]: |
8 |
Installation length EL[mm]: |
45 |
Display: |
Display unit(6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)) | Switching status(2 x LED, yellow) | Measured values(alphanumeric display, red/green 4-digit) |
Remarks: |
MW = Measured value | MEW = Final value of the measuring range |
Pack quantity: |
1 pcs. |
Connection: |
Connector: 1 x M12; coding: A; Contacts: gold-plated |