null
Autonics

Autonics Controllers Temperature Controllers TK4S SERIES TK4S-24RN

(No reviews yet) Write a Review
SKU:
TK4S-24RN
Weight:
500.00 Grams

Sold Out

Description

Autonics TK4S-24RN Temperature Controller – PID, Relay Output

The Autonics TK4S-24RN is a temperature controller supporting ON/OFF, P, PI, PD, and PID control methods. It accepts a range of thermocouple and RTD sensor types, along with analog voltage and current signals, allowing the input type to be selected according to the measurement requirement.

The controller features a 4-digit 7-segment LED display, a relay control output rated at 250VAC~ 3A, and a 50ms sampling cycle. It operates on a 100-240VAC~ 50/60Hz power supply and provides IP65 protection at the front panel.

Technical Specifications

Specification Value
Model TK4S-24RN
Display Method 4-digit 7-segment LED
Control Method ON/OFF, P, PI, PD, PID
Thermocouple Input K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II
RTD Input DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω
Analog Voltage Input 0-100mV, 0-5V, 1-5V, 0-10V
Analog Current Input 0-20mA, 4-20mA
Sampling Cycle 50ms
Control Output 1 Relay (250VAC~ 3A)
Option Output Alarm 1/2
Power Voltage 100-240VAC~ 50/60Hz
Protection Structure IP65 (front panel)
Ambient Temperature -10 to 50℃
Storage Temperature -20 to 60℃
Ambient Humidity 35 to 85% RH
Storage Humidity 35 to 85% RH
Insulation Type Double insulation or reinforced insulation
Dielectric Strength 2kV between the measuring input part and the power part
Compliance Markings Shown CE, UKCA, cRUus, RoHS, EAC

Environmental resistance ratings apply under non-freezing and non-condensing conditions.

Documents

Click to download the Autonics TK4S-24RN Datasheet

View AllClose

Warranty Information

One Year Warranty
View AllClose

Additional Information

Display method:
4-digit 7-segment LED
Control method:
ON/OFF control, P, PI, PD, PID control
Input specification:
Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω Analog: 0-100mV, 0-5V, 1-5V, 0-10V 0-20mA, 4-20mA
Sampling cycle:
50ms
Control output 1:
Relay(250VAC~ 3A)
Option input:
CT, Digital(DI-1)
Option output:
Alarm 1/2
Power supply:
100-240VAC~ 50/60Hz
Protection structure:
IP65(front panel)
Display accuracy_RTD:
•At room temperature(23℃±5℃):(PV ±0.3% or ±1℃, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2℃, select the higher one) ±1-digit
Display accuracy_Thermocouple:
•At room temperature(23℃±5℃):(PV ±0.3% or ±1℃, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2℃, select the higher one) ±1-digit
Display accuracy_Analog:
•At room temperature(23℃±5℃): ±0.3% F.S. ±1-digit •Out of range of room temperature: ±0.5℃% F.S. ±1-digit
Display accuracy_CT input:
±5% F.S. ±1-digit
Hysteresis(adjustable sensitivity):
RTD/Thermocouples: 1 to 100℃/℉(0.1 to 100.0℃/℉) variable Analog: 1 to 100-digit
Proportional band:
0.1 to 999.9℃/℉(0.1 to 999.9%)
Integral time:
0 to 9999 sec
Derivative time:
0 to 9999 sec
Control period:
Relay output, SSR drive output: 0.1 to 120.0 sec Current output or SSR drive output selectable: 1.0 to 120.0 sec
Manual reset:
0.0 to 100.0%
Environment_Ambient temperature:
-10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity:
35 to 85% RH, storage: 35 to 85% RH
Insulation type:
Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 2kV)
Weight_Basic module:
Approx. 150g(approx. 105g)
View AllClose