Multi Measuring Instruments
MCL-800DXR Digital Clamp Tester with 80mm x 74mm CT with Bluetooth
- SKU:
- MCL-800DXR
- Weight:
- 650.00 Grams
Description
MCL-800DXR Digital Clamp Tester with 80mm x 74mm CT with Bluetooth
The MCL-80DXR Digital Clamp Tester is an AC leakage current clamp meter designed for RMS current measurements from 0.01 mA to 1000 A. Its large 80 × 74 mm CT window accommodates conductors within the specified opening, while six measurement ranges with automatic range selection support both low-level leakage current and higher AC current measurements.
The MCL-80DXR features Bluetooth 4.2 connectivity for smartphone-based waveform viewing and measurement data access. Measurement records can also be accumulated on a server for graphical display and CSV output. A selectable 150 Hz low-pass filter, maximum-value hold, and data hold functions provide additional measurement flexibility.
Accuracy Specifications
Accuracy conditions: 23℃ ±5℃, 80%RH or less (50/60Hz)
| Function | Range / Resolution | Accuracy | Maximum Input / Protection |
|---|---|---|---|
| AC Current (50/60 Hz) | 20 mA / 0.01 mA | ±2.0% rdg ± 5 dgt | Not specified |
| 200 mA / 0.1 mA | ±2.0% rdg ± 5 dgt | ||
| 2 A / 1 mA | ±2.0% rdg ± 5 dgt | ||
| 20 A / 10 mA | ±2.0% rdg ± 5 dgt | ||
| 200 A / 0.1 A | ±2.0% rdg ± 5 dgt | ||
| 1000 A / 1 A | ±2.0% rdg ± 5 dgt |
Key Features –MCL-800DXR Digital Clamp Tester with 80mm x 74mm CT with Bluetooth
- Wide AC Current Measurement Range: Measures RMS AC current from 0.01 mA to 1000 A with automatic range selection.
- Large CT Window: 80 × 74 mm jaw opening for accommodating conductors within the specified dimensions.
- Bluetooth 4.2 Connectivity: Enables smartphone-based waveform display and access to measurement data.
- 150 Hz Low-Pass Filter: Selectable filtering function to reduce the influence of current components above 150 Hz.
- Measurement Hold Functions: Maximum-value hold and data hold functions for retaining readings on the LCD.
Documents
Catalog: e-ca_MCL-800D+.pdf
Instruction Manual: e-ma-MCL-800D+ series.pdf
Additional Information
Measuring method: |
Dual slope integration mode |
Accuracy: |
±3% of full scale(50/60Hz) |
Filter function: |
Low pass filter : 150Hz |
Measurement range: |
AC20mA/200mA/2A/20A/200A/1000A/Auto |
Max Memory function: |
"Max" mark on LCD with maximum value |
Auto power function: |
It power-off approximately 10-minutes after final operation. This function will be disabled during MAX-hold/ Bluetooth is on. |
Over range indication: |
Only the manual ranges are displayed up to 110% of the setting range (Excluding 1000A range). "OL" mark on LCD |
Data hold indication: |
"DH" mark on LCD with data hold value |
Low battery indication: |
"Battery" icon on LCD |
Sampling rate: |
2 times/sec |
Storage temperature: |
-10℃ to 60℃, 80%RH max. (Without condensation ) |
Power supply: |
1.5V (AM-4, LR03 or AAA)×3 |
Dimension: |
138(W)×237(H)×46(D)mm |
Accessories: |
Hard carrying case:1 || Instruction manual:1 || Batteries:3 |
Jaw opening capability: |
80mm x 74mm |
Withstanding Voltage: |
AC 3700V 1 minute max. (Between the core of CT and outer case) |
Limitation of circuit voltage: |
Less than AC 600V (EN61010 Installation category CAT III 300V) |
Interface: |
Bluetooth 4.2 |