Multi Measuring Instruments
MCL-1100D Digital Clamp Tester With Big CT Window (CE)
- SKU:
- MCL-1100D
- Weight:
- 1,900.00 Grams
Description
MCL-1100D Digital Clamp Tester With Big CT Window (CE)
The MCL-1100D Digital Clamp Tester is designed to measure AC load current and leakage current without disconnecting the conductor from the circuit. Its large 108 × 128 mm CT window accommodates conductors that require a wider clamp opening, while five manually selectable measurement ranges cover currents from 300 mA to 3000 A.
The tester uses True RMS AC measurement with an accuracy of ±1.5% of reading ±8 digits at 50/60 Hz. It also features a 150 Hz low-pass filter, data hold, and a DC 300 mV full-scale recorder output for each range. The MCL-1100D is specified for IEC 61010 Installation Category II at 600 V or Category III at 300 V.
Accuracy Specifications
Accuracy conditions: 23℃ ±5℃, 80%RH or less (50/60Hz)
| Function | Range / Resolution | Accuracy | Maximum Input / Protection |
|---|---|---|---|
| AC Current (50/60 Hz) | 300 mA / 0.1 mA | ±1.5% rdg ± 8 dgt | Not specified |
| 3 A / 0.001 A | ±1.5% rdg ± 8 dgt | ||
| 30 A / 0.01 A | ±1.5% rdg ± 8 dgt | ||
| 300 A / 0.1 A | ±1.5% rdg ± 8 dgt | ||
| 3000 A / 1 A | ±1.5% rdg ± 8 dgt |
Key Features –MCL-1100D Digital Clamp Tester With Big CT Window (CE)
- Large CT Window: 108 × 128 mm opening for clamping around large conductors without disconnecting the circuit.
- AC Current Measurement: Five manually selectable ranges from 300 mA to 3000 A for AC load and leakage current measurements.
- True RMS Measurement: AC-coupled True RMS measurement with an accuracy of ±1.5% rdg ±8 dgt at 50/60 Hz.
- Low-Pass Filter: Built-in 150 Hz low-pass filter for AC current measurements.
- Recorder Output: DC 300 mV full-scale output on each measurement range for connection to a recorder.
Documents
Catalog: e_ca_mcl-1100d.pdf
Instruction Manual: e-ma-mcl1100d.pdf
Additional Information
Measuring method: |
Dual slope integration mode |
Accuracy: |
See accuracy specifications in description tab |
Display: |
LCD, max. 3200 count with annunciators |
Measurement range: |
AC20mA/200mA/2A/20A/200A/1000A/Auto |
Auto power off function: |
The meter is set to power off Approx. 10 minute later after power on. |
Auto power function: |
The meter is set to power off Approx. 10 minute later after power on. |
Over range indication: |
"OL" mark on LCD |
Data hold indication: |
"DH" mark on LCD with data hold value |
Low battery indication: |
"Battery" icon on LCD |
Sampling rate: |
2 times/sec |
Storage temperature: |
-10℃ to 60℃, 80%RH max. (Without condensation ) |
Power supply: |
1.5V (AM-4, LR03 or AAA)×3 |
Dimension: |
194(W) x 341.5(H) x 52(D) mm |
Accessories: |
Battery (UM-4):2 || Carrying Case:1 || Instruction manual:1 |
Jaw opening capability: |
80mm x 74mm |
Withstanding Voltage: |
AC 3700V, 1 minute (between core of CT and outer case) |
Limitation of circuit voltage: |
Less than AC 600V |
Measuring function: |
AC load current, AC leakage current |
Safety standard: |
IEC61010-1, IEC-61010-2-032 Installation CategoryⅡ, 600V or CategoryⅢ, 300V |
Filter function: |
Low pass filter : 150Hz |
AC Conversion: |
AC coupled true rms responding |
DCmV output accuracy: |
±1.5% of Full Scale |
Output signal for recorder: |
DC 300mV for full scale for each range |
Battery life: |
Approx. 200 hours continuous |
Power consumption: |
Approx. 6mW |