null
Multi Measuring Instruments

FCM-400 Flexible AC/DC Current Tester

(No reviews yet) Write a Review
SKU:
FCM-400
Weight:
0.00 Grams

Sold Out

Description

FCM-400 Flexible AC/DC Current Tester

The FCM-400 Flexible AC/DC Current Tester is a portable current measuring instrument designed for AC and DC current measurements, particularly for monitoring anticorrosion currents in pipelines and diagnosing equipment deterioration on steel towers. Its flexible clamp sensor allows current measurement around conductors and objects that are difficult to access with conventional rigid clamps.

The instrument features a 450 mm CT opening diameter and three manually selectable measuring ranges of 3 A, 30 A, and 300 A, with a minimum resolution of 0.001 A. It measures AC current in RMS and DC current, using an LCD display with data hold functionality. A DC zero-adjustment function is also provided for offset correction before measurement.

Key Features – FCM-400 Flexible AC/DC Current Tester

  • AC/DC Current Measurement: Measures AC (RMS) and DC current with selectable 3 A, 30 A, and 300 A ranges.

  • Flexible Clamp Sensor: Bendable sensor with a 450 mm CT opening diameter for measuring around large or difficult-to-access objects.

  • High Measurement Resolution: Minimum resolution of 0.001 A.

  • Pipeline Anticorrosion Monitoring: Suitable for measuring anticorrosion currents in pipelines and diagnosing equipment deterioration on steel towers.

  • Data Hold and DC Zero Adjustment: Includes a data hold function and zero-offset adjustment for DC current measurements.

Documents

Instruction Manual: e-ma-fcm-100.pdf

View AllClose

Additional Information

Sensing method:
Split type CT with array of hole element sensors
Inside diameter of CT:
φ450mm
Lead length:
Approx.2m (From measuring unit to CT)
Display:
LCD max.3200 count with annunciators
Range selector:
3 range manual by rotary switch
Buzzer rumbling:
The buzzer rumbles when The power is turned on/turned off The range switch is changed The data hold switched on The measured data is displayed "OL" The continuity check finds that the resistance is below 40 Ω
Jaw opening capability:
55mmφ
Over range indication:
"OL" mark on LCD
Data hold indication:
"DH" mark on LCD
Sampling:
2 times/sec
Withstanding Voltage:
AC 2200V/1 minute
Data hold function:
Freeze the displayed value by D.H switch
Zero(offset) adjustment:
By zero(0) SET switch (DC current only)
Operating Temperature:
0℃ to 40℃, 80%RH max. ( Without condensation )
Storage Temperature:
-10~60℃, < 70%RH (without condensation)
Low battery indication:
"B" mark on LCD
Auto power off:
Approx. 10 minutes after power on
Power supply:
1.5V(AA size or UM-3) battery×6
Size:
Main unit:159(W)×105(H)×53(D)mm
Accessories:
Hard carrying case:1 || Instruction manual:1 || Test lead:1set || Batteries:2
Mesuring function:
AC (RMS)/DC current
Limitation of circuit voltage:
Less than AC 500V
Measuring ranges:
AC/DC 3A/30A/300A
A/D conversion:
Dual slope integration method
Accuracy:
±10%rdg±10dgt
Min. resolution:
0.001A
View AllClose