Description
Evaluation Unit for Speed Monitoring DD2503
Introduction – Evaluation Unit for Speed Monitoring DD2503
The Evaluation Unit for Speed Monitoring DD2503 from ifm electronic is a high-performance pulse evaluation system designed for precise monitoring of frequency, rotational speed, and machine cycles. Suitable for industrial automation environments, this device ensures reliable detection of overspeed and underspeed conditions. It features a luminous OLED display that provides clear indication of actual values and parameters, and simple front-panel programming buttons that make configuration intuitive and efficient.
With a universal power supply range (110–240 V AC/DC) and support for both PNP and NPN sensors, the DD2503 offers remarkable installation flexibility. Its integrated frequency-to-current converter enables proportional analog output signals (4–20 mA), making it ideal for integration into control and monitoring systems. Designed for easy DIN rail mounting, it ensures consistent performance and long-term reliability even under demanding industrial conditions.
Built to meet EN 61010 and EN 61000 EMC standards, this unit guarantees safe and interference-free operation. The DD2503 is widely used across process automation, machine control, and rotating equipment supervision applications. Available through Dubai Sensor, it offers proven performance and durability for automation systems throughout the UAE and MENA region.
Key Features & Benefits
- Reliable monitoring of overspeed and underspeed
- Microprocessor-based pulse evaluation system for accuracy and stability
- OLED display with real-time frequency and speed indication
- Simple programming via front buttons for easy setup
- Two relay and two transistor outputs for flexible switching functions
- Analog 4–20 mA output for process signal integration
- Adjustable hysteresis, delay time, and start-up delay
- Supports PNP/NPN sensor inputs (frequency ≤ 5 kHz)
- DIN-rail mountable compact housing (78 × 45 × 124.7 mm)
- Maintenance-free, long service life (MTTF ≈ 152 years)
- Compliant with EN 61010 and EN 61000-6-2/6-4 standards
Technical Specifications – Evaluation Unit for Speed Monitoring DD2503
|
Category |
Specification |
|
Power Supply |
110–240 V AC / 27 V DC |
|
Power Consumption |
3 W |
|
Sensor Supply |
19.6–27.7 V DC (SELV), ≤15 mA |
|
Input Frequency Range |
0.1–1000 Hz / 1–60000 imp/min |
|
Input Type |
1 pulse input (PNP/NPN compatible) |
|
Relay Outputs |
2 changeover contacts, ≤6 A (250 V AC / 30 V DC) |
|
Transistor Outputs |
2 × PNP type, externally supplied |
|
Analog Output |
4–20 mA, load ≤500 Ω |
|
Display |
OLED 128×64 px (luminous) + status LEDs |
|
Housing Dimensions |
78 × 45 × 124.7 mm |
|
Mounting |
DIN rail (TH35, EN 60715) |
|
Ambient Temperature |
−40…+60 °C |
|
Storage Temperature |
−40…+85 °C |
|
Humidity |
80 % (31 °C) → 50 % (40 °C) |
|
Protection |
Housing: IP50, Terminals: IP20 |
|
Pollution Degree |
2 |
|
Overvoltage Category |
II |
|
Weight |
381.5 g |
|
MTTF (Typical) |
152 years |
|
Compliance |
EN 61010, EN 61000-6-2, EN 61000-6-4, EMV 89/336/EWG |
Standards & Certifications
The Evaluation Unit for Speed Monitoring DD2503 complies with international standards ensuring safety, electromagnetic compatibility, and operational integrity:
- EN 61010: Electrical equipment safety requirements
- EN 61000-6-2 / EN 61000-6-4: EMC immunity and emission standards
- EMV 89/336/EWG: Electromagnetic compatibility directive
- Overvoltage Category II, Pollution Degree 2
Applications & Industries
- Industrial automation and machine control systems
- Conveyor belt and motor speed supervision
- Pump and fan overspeed or underspeed detection
- Wind turbine and generator speed monitoring
- Shaft rotation and spindle control in production lines
- Process monitoring systems requiring frequency feedback
- Widely applied in UAE and MENA manufacturing and process industries
Installation, Commissioning & Maintenance
- Mount securely on a 35 mm DIN rail within an IP40 or higher-rated cabinet
- Ensure adequate air circulation to prevent heat buildup
- Connect all terminals according to the wiring diagram provided by ifm
- Configure switching points, hysteresis, and delay functions using front buttons
- The OLED display shows actual readings and parameter settings
- Device is maintenance-free—no user-serviceable components inside
- Dispose of according to environmental and safety regulations
Why Choose Evaluation Unit for Speed Monitoring DD2503
The DD2503 combines precision, safety, and ease of use in one compact housing. Its universal AC/DC supply range and multiple outputs enable seamless integration into any industrial system. The high-quality OLED display, intuitive programming, and robust performance make it an excellent choice for continuous speed monitoring in demanding environments.
Choosing the Evaluation Unit for Speed Monitoring DD2503 ensures reliable protection, optimized machine performance, and long-term operational safety. Available through Dubai Sensor, it provides trusted quality for industrial applications across the UAE and MENA region.
Ordering Guide
- Confirm required power supply (110–240 V AC or 27 V DC).
- Verify compatibility with connected sensors (PNP/NPN type).
- Determine desired output configuration (relay, transistor, or analog).
- Mount the unit on DIN rail and complete electrical connections.
- Configure settings using the front panel display and buttons.
- For authorized supply and support, contact Dubai Sensor, the official distributor of ifm electronic products in the region.
Evaluation Unit for Speed Monitoring DD2503
Q1: What is the main function of the Evaluation Unit for Speed Monitoring DD2503?
A: The DD2503 monitors rotational speed, frequency, and machine cycles. It detects overspeed or underspeed conditions using pulse signals from PNP or NPN sensors and provides relay, transistor, and analog output signals for control or safety applications.
Q2: What types of sensors can be connected to the DD2503?
A: The unit supports PNP and NPN-type sensors for pulse signal input. It supplies 19.6–27.7 V DC (SELV, ≤15 mA) for connected sensors.
Q3: How many outputs does the DD2503 have?
A: It features two relay outputs, two PNP transistor outputs, and one analog 4–20 mA output, offering flexible integration into various control systems.
Q4: What is the measuring range of the DD2503?
A: The unit can measure frequencies from 0.1 to 1000 Hz or rotational speeds from 1 to 60000 impulses per minute (imp/min).
Q5: Can the DD2503 operate on both AC and DC power?
A: Yes. It operates with a wide supply voltage range of 110–240 V AC or 27 V DC, ensuring compatibility with diverse installations.
Q6: What display and programming options does the device offer?
A: The DD2503 features a 128×64 pixel OLED display for clear visualization of measured values and parameters. It includes three programming buttons for easy parameter setup and adjustment.
Q7: What protection ratings apply to the DD2503?
A: The device housing is rated IP50, and the terminal section is rated IP20, making it suitable for installation inside protective control cabinets.
Q8: What environmental conditions can it withstand?
A: It operates reliably in ambient temperatures from −40 °C to +60 °C, with storage temperatures down to −85 °C, and a maximum relative humidity of 80 % (31 °C).
Q9: Does the DD2503 require maintenance?
A: No. The unit is maintenance-free and contains no user-serviceable parts. It is designed for long-term reliability with a mean time to failure (MTTF) of approximately 152 years.
Q10: Where can I purchase or get support for the DD2503?
A: The Evaluation Unit for Speed Monitoring DD2503 is available through Dubai Sensor, the authorized distributor of ifm electronic products in the UAE and MENA region.
Documents
Additional Information
Housing: |
rectangular |
Dimensions[mm]: |
78 x 45 x 124.7 |
Design: |
housing for DIN rail mounting |
Application: |
pulse evaluation system with microprocessor for frequency; rotational speed; speed; pulses and machine cycles |
Nominal voltage AC[V]: |
110...240 |
Nominal voltage DC[V]: |
27 |
Nominal voltage tolerance[%]: |
< 10 |
Nominal voltage tolerance 2[%]: |
20...10 |
Nominal frequency AC[Hz]: |
50...60 |
Power consumption[W]: |
3 |
Auxiliary energy for sensors DC[V]: |
19.6...27.7; (SELV, ≤ 15 mA) |
Number of inputs and outputs: |
Number of analog outputs: 1; Number of relay outputs: 2 |
Number of relay outputs: |
2 |
Contact rating: |
6 A (250 V AC, 30 V DC); B300, R300; (resistive load) |
Number of analog outputs: |
1 |
Analog current output[mA]: |
4...20 |
Max. load[Ω]: |
500; (Min. load: 20 [Ω]) |
Setting range Hz[Hz]: |
0.1...1000 |
Setting range[Imp/min]: |
1...60000 |
Ambient temperature[°C]: |
-40...60 |
Storage temperature[°C]: |
-40...85 |
Max. relative air humidity[%]: |
80; (40 °C: 50 %) |
Protection: |
IP 50 |
Protection rating terminals: |
IP 20 |
Degree of soiling: |
2 |
EMC: |
EN 61010(2011), EMV 89/336/EWG, EN 61000-6-2(2005), EN 61000-6-4(2007) |
MTTF[years]: |
152 |
Weight[g]: |
381.5 |
Type of mounting: |
Mounting on DIN rail; (TH35 (EN 60715)) |
Material: |
housing: plastics |
Display: |
OLED display, 128 x 64 pixels luminous - Switching status: LED, green |
Remarks: |
the device complies with overvoltage category II |
Pack quantity: |
1 pcs. |
-: |
dual-chamber terminals: 2 x ...2.5 mm²; AWG 14 |