null

DATEXEL Temperature Transmitter Device In-Head Mounting Temperature Transmitter DAT1061

Write a Review
SKU:
DAT1061
MPN:
DAT1061
Weight:
500.00 Grams
Minimum Purchase:
1 unit
Shipping:
Calculated at Checkout
$120.00

Description

DAT1061 from Datexel is a hockey puck (headed mount) Isolated Temperature Transmitter. The input is Galvanic Isolated from the output at 1500 Vac. The inputs, ranges, zero and span are configurable by PC. The input can be configured for RTD's (Pt100, Pt1000, Ni100 and Ni1000), mV up to 700mV with a minimum span of 2 mV, Potentiometers up to 50 kΩ and Resistance up to 2000 Ohms with a minimum span of 10 Ohms. It is also possible to linearize the input signal and output signal. The output signal can be damped with the Damping feature in the Prosoft Software. This damping is adjustable for up to 30 seconds. The output can be configured to provide the normal 4-20mA output or can be programmed to provide a 20-4mA output.

Resistor and RTD's sensors can be programmed to accept 3 or 4 wires so compensation wires can be used. The configuration uses the Prosoft software and the Prodat USB programming device is also available from DATEXEL. It is available for either USB or an RS232 port.

DAT1061 from Datexel comes with the following features:

  • Configurable input for RTD, mV, Resistance, and Potentiometer.
  • Galvanic isolation at 1500 Vac.
  • 4 ÷ 20 mA configurable output on the current loop.
  • Configurable by Personal Computer.
  • Configurable by interface PRODAT05 or PRODAT06 without the power loop connected.
  • High accuracy.
  • On-field reconfigurable.
  • EMC compliant with CE mark.
  • Suitable for DIN B in-head mounting.
  • Option for DIN rail mounting in compliance with EN 50022 (DIN RAIL Option).

Brand Information

Datexel products are made to the very highest standards and all products carry the CE mark, and since March 2015 all slim-line products and DAT3000 modules carry the UL and CSA mark. Datexel obtained ISO 9001 in 1996 and now has the current standard UNI EN ISO 9001:2000 (issued in 2001). Datexel's signal conditioners also carry the ATEX 94/9/EC approval for safe environments. In July 2006, Datexel confirmed its products to the RoHS Directive Standard (2002/95/EC) which imposes restrictions on the use of dangerous substances for the manufacturing of electric and electronic equipment. Situated in Jupiter, Florida USA.

View AllClose

Warranty Information

One Year Warranty.
View AllClose

Additional Information

input:
none
Input signal type:
RTD, Potentiometer, Voltage, Resistance.
Input calibration:
RTD > of ±0.1% f.s. or ±0.2°C. Low res. > of ±0.1% f.s. or ±0.15 Ω. High res. > of ±0.2% f.s. or ±1 Ω. mV > of ±0.1% f.s. or ±10 uV.
Input impedance:
mV >= 10 MΩ.
output:
none
Output type DC:
Min. 4mA. Max. 20mA.
Output type Reverse Current:
Min. 20mA. Max. 4mA.
Output calibration:
Current ± 7 uA.
Linearity:
RTD ± 0.1 % f.s.
Line resistance influence:
mV <=0.8 uV/Ohm. RTD 3 wires 0.05%/Ω (50Ω balanced max.). RTD 4 wires 0.005%/ Ω (100Ω balanced max.).
RTD excitation current:
Typical 0.350 mA.
Thermal drift:
0.01 % of f.s./°C.
Burnout values:
Max. output value about 20.5 mA. Min. output value about 3.8 mA. Max. fault value about 21.6 mA. Min. fault value about 3.5 mA.
Damping time constant:
Selectable from 0.3 to 30 s. Value 0: function not active.
Response time (10÷ 90%):
About 400 ms.
Power supply:
Power supply voltage 7 …32 Vdc. Reverse polarity protection 60 Vdc max.
Isolation voltage:
Input – Power supply 1500 Vac, 50 Hz,1 min.
Temp. and humidity:
Operative temperature -40°C …+85°C. Storage temperature -40°C …+85°C. Humidity (not condensed) 0 …90 %.
Housing:
Material PC + ABS V0. Mounting DIN B head or bigger. Weight about 50 g. Dimensions Ø= 43 mm ; H = 24 mm
EMC (for industrial environments):
Immunity EN 61000-6-2. Emission EN 61000-6-4.
View AllClose