CAMLogic CLC40 Series Conductive Level Indicator

Introduction – CAMLogic CLC40 Series Conductive Level Indicator

The CAMLogic CLC40 Series Conductive Level Indicator is designed for reliable and independent monitoring of two liquid level thresholds in conductive media. Using the principle of current flow between stainless-steel electrodes immersed in the liquid, the device activates one or two SPDT relay outputs for control or alarm functions.

Equipped with adjustable sensitivity and a programmable delay system, the CLC40 Series ensures accurate detection even in liquids with varying conductivity, minimizing false signals. Its reinforced polyamide housing and AISI 316 stainless steel electrodes provide excellent durability in industrial environments.

Installation is straightforward—requiring no special tools—and the device can be mounted in vertical or oblique positions, offering flexibility for various tank configurations. The CLC40 Series is widely used in water treatment, food processing, and industrial automation applications, including operations across the UAE and MENA regions, where precise liquid level control is critical.

Distributed officially by Dubai Sensor, this instrument combines Italian engineering precision with dependable on-site performance for demanding process conditions.

Key Features & Benefits

  • Dual-point level control (minimum and maximum thresholds)

  • Two independent SPDT relay outputs (8 A @ 250 VAC)

  • Configurable delay (0 / 2 / 6 / 10 seconds) to prevent false triggering

  • Adjustable sensitivity for liquids with conductivity ≥ 5 µS/cm

  • Wide operating range: –10 °C to +90 °C process temperature

  • Robust construction: PA6 Nylon housing and AISI 316 electrodes

  • High ingress protection: IP65 / IP67 for indoor and outdoor use

  • Simple installation: no specialized tools required

  • Flexible mounting: vertical or angled installation

  • Maintenance-free operation under normal conditions

Technical Specifications – CAMLogic CLC40 Series Conductive Level Indicator

Parameter

Specification

Power Supply

115/230 VAC (50/60 Hz) / 24/48 VAC (50/60 Hz) / 24 VDC ±15 %

Power Consumption

1 W

Signal Output

2 × SPDT relays

Contact Rating

8 A @ 250 VAC (10 A max)

Minimum Liquid Conductivity

5 µS/cm (20 mm electrode coverage)

Sensitivity

Adjustable via trimmer

Intervention Delay

0 / 2 / 6 / 10 seconds (DIP switch)

Process Temperature

–10 °C to +90 °C

Ambient Temperature

–10 °C to +70 °C

Maximum Pressure

10–15 bar

Protection Rating

IP65 / IP67

Housing Material

Reinforced polyamide (PA6 nylon)

Electrode Material

AISI 316 / EN 1.4401 stainless steel

Process Connection

G 1 ½″ (BSPP)

Cable Entry

G ½″ (BSPP)

Cable Size

0.5–2.5 mm² (14 AWG)

Weight

2.2 kg

Standard Electrode Length

920 mm (adjustable 80–6000 mm)

Standards & Certifications

  • CE Compliance under the following European Directives:

    • 2011/65/EU – RoHS

    • 2014/30/EU – EMC

    • 2014/35/EU – Low Voltage Directive

    • 1935/2004/EU – Food Contact Compliance

  • Protection classes: IP65 / IP67

  • Safety symbols: per IEC 60417 and ISO 7000 standards

Applications & Industries

  • Level detection and pump control in storage tanks and vessels

  • Overflow and dry-run protection for process systems

  • Water and wastewater treatment

  • Food and beverage production (food-contact compliant)

  • Chemical and pharmaceutical process tanks

  • Industrial automation and fluid handling systems across UAE / MENA

Installation, Commissioning & Maintenance

  • Install vertically or obliquely; avoid direct liquid impact on electrodes.

  • Use flexible cables (0.5–2.5 mm²) and ensure power disconnection before wiring.

  • Electrode length may be shortened to adjust detection height (minimum 80 mm).

  • Adjust sensitivity with the trimmer while monitoring LED R1 and R2 indicators.

  • Clean electrodes periodically to remove any non-conductive buildup.

  • Ensure qualified personnel perform all setup and maintenance tasks.

Why Choose the CAMLogic CLC40 Series Conductive Level Indicator

The CAMLogic CLC40 Series delivers precise, dependable level detection for conductive liquids. Its dual-relay configuration allows independent monitoring of both minimum and maximum thresholds, reducing downtime and preventing overflows or pump damage.

Built to withstand harsh industrial conditions, it combines robust mechanical design, flexible configuration, and maintenance-free performance, making it an ideal choice for engineers and process integrators requiring durable and adaptable level-control solutions.

Ordering Guide

  1. Select the model according to required supply voltage (115/230 VAC, 24/48 VAC, or 24 VDC).

  2. Specify electrode length (standard 920 mm; available 80–6000 mm).

  3. Confirm process connection (G 1 ½″ BSPP) and mounting position.

  4. Define application environment (temperature, conductivity, and liquid type).

  5. Place your order through Dubai Sensor, the official distributor of CAMLogic instruments in the UAE and MENA region.

 CAMLogic CLC40 Series Conductive Level Indicator

Q1: What is the CAMLogic CLC40 used for?
A: The CLC40 is a conductive level indicator designed to detect and control one or two liquid level thresholds in tanks or vessels containing conductive liquids. It is ideal for applications such as overflow protection, pump control, and dry-run prevention.

Q2: How does the CLC40 detect liquid levels?
A: The device operates by measuring a small alternating current between stainless-steel electrodes immersed in the liquid. When the liquid reaches the electrode level, the current activates the corresponding relay output.

Q3: What types of liquids can be measured with the CLC40?
A: The CLC40 is suitable for conductive liquids with a minimum conductivity of 5 µS/cm. It is not recommended for greasy or oily liquids that form insulating layers on electrodes.

Q4: Can the sensitivity of the CLC40 be adjusted?
A: Yes. Sensitivity is adjustable via a trimmer located on the circuit board, allowing the device to adapt to liquids with lower conductivity.

Q5: What are the available power supply options?
A: The CLC40 operates with 115/230 VAC, 24/48 VAC, or 24 VDC power supplies, consuming just 1 watt.

Q6: Does the CLC40 offer delay settings to avoid false signals?
A: Yes. The built-in DIP switch allows users to set a signal delay of 0, 2, 6, or 10 seconds, minimizing false triggering due to turbulence or splashes.

Q7: How is the device installed?
A: The CLC40 can be mounted vertically or obliquely using its G 1½″ BSPP threaded connection. No special tools are required for installation.

Q8: What maintenance does the CLC40 require?
A: The sensor requires minimal maintenance. Periodically clean the electrodes to remove non-conductive deposits such as limestone or residue that could affect measurement accuracy.

Q9: What is the protection class of the CLC40?
A: The unit is rated IP65/IP67, ensuring protection against dust and water jets for indoor or outdoor use.

Q10: What standards and certifications does the CLC40 comply with?
A: The product conforms to CE, RoHS (2011/65/EU), EMC (2014/30/EU), LVD (2014/35/EU), and Food Contact (1935/2004/EU) directives.

Q11: What is the warranty period for the CLC40?
A: CAMLogic provides a 24-month warranty from the date of shipment, covering repair or replacement of defective parts under normal operating conditions.