Autonics
Autonics Counter & Timer Counters CT4S-1P4
- SKU:
- CT4S-1P4
- MPN:
- CT4S-1P4
- Weight:
- 220.00 Grams
- Minimum Purchase:
- 1 unit
Description
Autonics CT4S-1P4 Programmable Digital Counter/Timer
4-digit, DIN W 48 × H 48 mm, 7-segment LED
The Autonics CT4S-1P4 is a programmable digital counter and timer featuring a 4-digit 7-segment LED display, 1-stage preset control output, relay contact output, and NPN open collector output. The unit is designed for industrial counting and timing applications requiring reliable operation, flexible input modes, and multiple output functions.
As a quick report, this counter/timer provides:
4-digit 7-segment LED display
DIN W 48 × H 48 mm panel size
1-stage preset control output
SPDT (1c) relay output
NPN open collector output
Power supply: 100-240 VAC, 50/60 Hz
Counter and timer integrated functions
IP65 front panel protection
Voltage input (PNP) and no-voltage input (NPN)
Maximum counting speed up to 10 kHz
Approx. 10 years memory retention
Counter Functions
The CT4S-1P4 supports various counting modes for industrial automation systems.
- Count Up
- Count Down
- Count Up/Down
- Counting range: -999 to 9999
- Decimal point scaling up to 3 digits
- Selectable counting speeds: 1, 30, 1k, 5k, 10k cps
- Count Start Point setting function
- Batch counting function
- TOTAL and HOLD display modes
Timer Functions
The timer function offers flexible operation and multiple timing ranges.
- POWER ON START
- SIGNAL ON START
- Count Up timing
- Count Down timing
- Setting range from 0.001 seconds to 9999 hours
- TOTAL display mode
- HOLD display mode
- On-Time display mode
Output Operations
The CT4S-1P4 supports various timer and control output operations.
- SIGNAL ON DELAY
- POWER ON DELAY
- FLICKER
- INTERVAL
- SIGNAL OFF DELAY
- ON-OFF DELAY
INTEGRATION TIME
- INT2
- NFD.1
- INTG
Inputs and Outputs
Signal Input Method: Voltage input (PNP), No-voltage input (NPN)
Control Output: 1-stage preset
Relay Output: SPDT (1c), 1 output
NPN Open Collector Output: 1 output
External Power Supply: 12 VDC ±10%, Max. 100 mA
Minimum Signal Width: 1 ms / 20 ms selectable
Protection and Environmental Conditions
The CT4S-1P4 is designed for reliable operation in industrial environments.
Front panel protection: IP65
Ambient temperature: -10 to 55°C
Storage temperature: -25 to 65°C
Ambient humidity: 35 to 85% RH
Storage humidity: 35 to 85% RH
Environment resistance rated at no freezing or condensation
Industries / Applications
Packaging Machinery
Conveyor Systems
Plastic Injection Molding
Rubber Extrusion Processes
Food Processing Equipment
Automated Production Lines
Material Handling Systems
Industrial Control Panels
Click on the following link to view other Autonics Counter & Timer products.
Brand Information
“Autonics” is a leading provider of automation solutions from South Korea. They develop and manufacture a wide range of automation products that are marketed worldwide. Their core products include various sensors, controllers, and motion devices, measuring equipment, laser marking systems, connection equipment and more. Autonics products are trusted and adopted by engineers in various industrial applications and their technology is widely applied in day-to-day automation devices.
With 12 international offices in South Korea, China, Japan, India, Vietnam, Indonesia, Malaysia, Russia, Turkey, USA, Brazil, Mexico, Autonics is able to provide comprehensive automation solutions for their customers across the globe.
Data Sheet
Click to download the Autonics CT4s-1p4 DatasheetAdditional Information
Digits: |
4. |
Digit size: |
Single preset 11mm. |
Digit size: |
Single preset 8mm. |
Power supply: |
Single preset 100-240VAC 50/60Hz |
Power supply: |
Single preset 24VAC 50/60Hz/24-48VDC. |
Allowable voltage range: |
90 to 110% of voltage rated. |
Power consumption: |
Single preset Max. 12VA. |
Power consumption: |
Single preset AC max. 10VA/DC Max: 8W |
INA/INB max. counting speed: |
Selectable 1cps/30 cps/5k cps/10k cps. |
Min. input signal width: |
Counter Reset signal. Selectable 1ms, 20ms. |
Min. input signal width: |
Timer INA, INB RESET: Selectable 1ms, 20ms. |
input: |
Selectable Voltage input or No-voltage input. [Voltage input] input impedance is 5.4KΩ, ‘H’ level: 5-30VDC, ‘L’ level 0-2VDC. [No-voltage input] short-circuit impedance Max. 1kΩ, residual voltage, Max.2VDC. |
One-shot output: |
Count, timer: Selectable 0.01s to 99.99s. |
Control output: |
Without com. Solid-state output Dual preset: 1NPN open collector. Single preset: 1NPN open collector. |
Control output: |
Without com. Solid-state output ----. |
Control output: |
Without com. Contact output 250VAC, 5A resistive load. |
Control output: |
Without com. Solid-state output 30VDC Max. 100mA max. |
External sensor power: |
12VDC ±10%, 100mA max. |
Memory retention: |
10 years (when using non-volatile semiconductor memory type). |
Timer: |
Repeat error Power ON start: Max ±0.1 0.01%, 0.05s. Signal start: Max ±0.01%, ±0.03s. |
Timer: |
SET error Power ON start: Max ±0.1 0.01%, 0.05s. Signal start: Max ±0.01%, ±0.03s. |
Timer: |
Voltage error Power ON start: Max ±0.1 0.01%, 0.05s. Signal start: Max ±0.01%, ±0.03s. |
Timer: |
Temp. error Power ON start: Max ±0.1 0.01%, 0.05s. Signal start: Max ±0.01%, ±0.03s. |
Insulation resistance: |
100MΩ (at 500VDC megger). |
Dielectric strength: |
2000VAC 50/60Hz for 1 min. |
Noise strength: |
±2KV the square wave noise (pulse width: 1µs) by the noise simulator. |
Vibration: |
Mechanical 0.75mm Amp. at freq. 0f 10-55Hz (for 1min.) in each X, Y, Z directions for 1 hour. |
Vibration: |
Malfunction 0.5mm Amp. at freq. 0f 10-55Hz (for 1min.) in each X, Y, Z directions for 10 min. |
Shock: |
Mechanical 300m/s2 (approx. 30G) in each X, Y, Z directions for 3 times. |
Shock: |
Malfunction 100m/s2 (approx. 10G) in each X, Y, Z directions for 3 times. |
Relay life cycle: |
Mechanical Min. 10,000,000 operations. |
Relay life cycle: |
Electrical Min. 100,000 operations. |
Protection: |
IP65 (front panel only). |
Environment: |
Ambient temp. -10~55â—¦C, storage -25~65â—¦C. |
Environment: |
Ambient humidity 35-85% HR, storage: 35-85% HR. |
Approval: |
CE. |
Unit weight: |
Approx. 159g. |
Communication Specifications: |
none |
Protocol: |
Mobus RTU (16 bit CRC). |
Connection method: |
RS485. |
Application standard: |
Compliance with EIA RS485. |
No. of connections: |
31, it is available to set address 1 to 127. |
Communication method: |
Half duplex. |
Synchronous method: |
Asynchronous. |
Communication distance: |
Within max. 800M. |
Communication speed: |
2,400, 4,800, 9,600, 19,200, 38,400bps (Factory default: 9600bps). |
Response waiting time: |
5-99ms (factory default: 20ms). |
Start bit: |
1 bit (fixed). |
Data bit: |
8 bits (fixed). |
Parity bit: |
None, even, odd (factory default: none). |
Stop bit: |
1, 2 bit (factory default: 2 bit). |