Autonics
Capacitive Sensor M18, AC 2 wire, Normally Closed - CR18-8AC
- SKU:
- CR18-8AC
- Weight:
- 500.00 Grams
Description
CR18-8AC AC 2-Wire Sensor - M18, 8mm Sensing Distance
Product Introduction
The CR18-8AC is an AC 2-wire sensor with a 100–240VAC~ power specification and Normally Closed control output. Its M18 sensing side diameter and 8 mm sensing distance provide the key mechanical and sensing parameters needed for initial model selection.
The sensor has an IP66 protection structure and operates within an ambient temperature range of -25 to 70℃ under non-freezing and non-condensing conditions. Its technical characteristics include a 20Hz average response frequency, Max. 2.2mA leakage current, and hysteresis of Max. 20% of the sensing distance.
Key Decision Features
- AC 2-wire type, 100–240VAC~
- Normally Closed control output
- M18 sensing side diameter
- 8 mm sensing distance
- IP66 protection structure
Technical Specifications
| Specification | Value |
|---|---|
| Wire type and power | AC 2-wire type, 100–240VAC~ |
| Sensing side diameter | M18 |
| Sensing distance | 8mm |
| Standard sensing target | 50×50×1mm (iron) |
| Response frequency | 20Hz (average value) |
| Leakage current | Max. 2.2mA |
| Control output | Normally Closed |
| Material | Polyamide 6 |
| Protection structure | IP66 |
| Ambient temperature | -25 to 70℃; storage: -30 to 80℃ |
| Ambient humidity | 35 to 95% RH; storage: 35 to 95% RH |
| Hysteresis (distance) | Max. 20% of sensing distance |
The specifications above preserve the supported values and qualifiers from the supplied CR18-8AC datasheet. cr18-8ac
Which CR Capacitive Proximity Sensor Is Right for You?
| Feature | CR18-8AC | CR18-8DN | CR18-8DP |
|---|---|---|---|
| Sensor Diameter | M18 | M18 | M18 |
| Sensing Distance | 8 mm | 8 mm | 8 mm |
| Power Supply / Wiring | 100-240 VAC / 2-wire | 12-24 VDC / 3-wire | 12-24 VDC / 3-wire |
| Output Type | AC 2-wire | NPN | PNP |
| Output Operation | Normally Closed (NC) | Normally Open (NO) | Normally Open (NO) |
| Response Frequency | 20 Hz | 50 Hz | 50 Hz |
Important Note
The specified ambient temperature and humidity ranges apply under non-freezing and non-condensing conditions.
Additional Information
Wire type and power: |
AC 2-wire type |
Sensing side diameter: |
M18 |
Sensing distance: |
8mm |
Standard sensing target: |
50×50×1mm(iron) |
Response frequency: |
20Hz |
Current specification: |
Leakage current: Max. 2.2mA |
Control output: |
Normally Closed |
Material: |
Polyamide 6 |
Protection structure: |
IP66 |
Environment_Ambient temperature: |
-25 to 70℃, storage: -30 to 80℃ |
Environment_Ambient humidity: |
35 to 95% RH, storage: 35 to 95% RH |
Hysteresis(distance): |
Max. 20% of sensing distance |