Endress+Hauser
Hydrostatic Level measurement Deltapilot FMB50
- SKU:
- Hydrostatic Level measurement Deltapilot FMB50 Series
- MPN:
- Hydrostatic Level measurement Deltapilot FMB50
- Weight:
- 0.00 Grams
Description
Application
The Deltapilot FMB50 is a compact transmitter featuring a condensate-resistant Contite measuring cell, ideal for process and hygienic applications. It is designed for level measurement in liquids and paste-like media within open or closed containers, and it operates reliably even in the presence of foam. It is also suitable for integration into SIL2 safety systems.
This transmitter is capable of both level and pressure measurement, with options for threaded, flanged, and flush-mounted hygienic process connections.
- Process temperature range: –10 to +100°C (14 to 212°F) (up to +135°C (275°F) for a maximum of 30 minutes)
- Measuring range: 0.1 to 10 bar (1.5 to 150 psi)
- Accuracy: ±0.2%, with an optional ±0.1%
The FMB50 comes with international explosion protection certificates, overfill prevention (WHG), SIL certification, and hygienic approvals.
Benefits
- Contite measuring cell: Hermetically sealed and condensate-resistant, offering high reference accuracy of ±0.2%, with an optional ±0.1%, and minimal temperature-related effects.
- Modular design: Facilitates easy replacement of the display or electronics.
- System integration: Compatible with HART, PROFIBUS PA, and FOUNDATION Fieldbus for seamless and independent integration.
- User-friendly commissioning: Easy setup through a menu-guided interface, supporting 4 to 20mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus.
- Global applicability: Supported by a comprehensive range of international approvals.
SPECIFICATIONS
Pressure Specifications
Measuring principle
|
Hydrostatic pressure
|
Characteristic
|
Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
|
Supply voltage
|
4...20 mA HART: 10,5...45 VDC (Non Ex) Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
|
Reference Accuracy
|
Standard 0.2 % Optional 0.1 %
|
Long term stability
|
0.05 % of URL/ year
|
Process temperature
|
-10°C...100°C (14°F...212°F)
|
Ambient temperature
|
-40°C...85°C (-40°F...185°F)
|
Measuring cell
|
100 mbar...10 bar (1.5 psi...150 psi)
|
Smallest calibratable span
|
10 mbar (1.45 psi) |
Vacuum resistance
|
0 mbar abs.
|
Max. Turn down
|
100:1
|
Max. overpressure limit
|
40 bar (600 psi)
|
Process connection
|
Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K
|
Process connection hygienic
|
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD
|
Material process membrane |
316L, AlloyC Gold-Rhodium
|
Material gasket
|
None, measuring cell welded
|
Fill fluid
|
Inert oil, Synthetic oil
|
Material housing
|
316L, Die-cast aluminum
|
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
|
Safety approvals
|
Overfill protection WHG SIL
|
Design approvals
|
EN10204-3.1 NACE MR0103
|
Hygienic approvals |
3A, EHEDG CoC ASME-BPE
|
Marine approvals |
GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals
|
KTW/ NSF/ ACS |
Specialities |
Modularity to differential pressure and process pressure devices (replacable display, universal electronics) Diagnostic functions |
Continuous / Liquids Specifications
Measuring principle
|
Hydrostatic
|
Characteristic / Application
|
Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed
|
Specialities
|
Modularity to differential pressure and process pressure devices (replacable display, universal electronics) Diagnostic functions Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
|
Supply / Communication
|
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex)
|
Accuracy |
Standard 0.2% Optional 0.1%
|
Long term stability
|
0.05% of URL/year |
Ambient temperature
|
-40°C...85°C (-40°F...185°F)
|
Process temperature
|
-10°C...100°C (14°F...212°F)
|
Process pressure / max. overpressure limit
|
40 bar (600 psi)
|
Pressure measuring range
|
100 mbar...10 bar (1.5 psi...150 psi)
|
Main wetted parts
|
Alloy C 316L optional coating AuPt
|
Process connection
|
Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
Process connection hygienic
|
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD
|
Max. measurement distance
|
100m (328ft) H2O
|
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
|
Safety approvals
|
Overfill protection WHG SIL
|
Design approvals |
EN10204-3.1 NACE MR0103
|
Hygienic approvals
|
3A, EHEDG CoC ASME-BPE
|
Marine approval
|
GL/ ABS/ LR/ BV/ DNV
|
Drinking water approvals
|
KTW/ NSF/ ACS
|
Options
|
Separate housing Initial device settings Overvoltage protection |
Application limits
|
If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+HauserFMB50 Series datasheet.