The CYK10 ensures a completely watertight connection between Memosens sensors and the transmitter. Its inductive coupling prevents contact corrosion and ensures galvanic isolation between the transmitter and the medium. Say goodbye to issues like limited cable lengths, interference from external potentials, or moisture, and enjoy safe, reliable signal transmission.The Memosens data cable CYK10 is utilized in Memosens systems for measuring the following parameters:
pH/ORP
Dissolved oxygen (amperometric)
Conductive conductivity
Disinfection
Benefits
Ensures maximum process safety through non-contact, inductive, and digital signal transmission: no contact corrosion, completely watertight, and free from interference.
Enhances measuring point availability: Digital data transmission includes automatic error alerts if the signal is interrupted.
Offers greater flexibility in plant design and installation with cable lengths of up to 100 meters.
Certified for use in hazardous areas.
Documents
You may want to read this product's catalog. If so, please click to view the CYK10 Series datasheet.
SPECIFICATIONS
pH Specification
Measuring principle
Potentiometric
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug-head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Measuring range
High impedance cable not necessary
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against humidity
Material
Cable sheath: TPE, Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch), Cores: 2x2 cores, twisted pairs, Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Process pressure
max. 50 bar/725 psi at 135°C/275°F
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6, FM, CSA IS Cl.1 Div 1 Gr. A-D, ATEX, NEPSI II 3G Ex nL IIC, TIIS
Ingress protection
IP68
Additional certifications
Also available as TÜV approved SIL version
ORP/Redox Specification
Measuring principle
Sensor ORP / Redox
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug-head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against humidity
Material
Cable sheath: TPE, Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch), Cores: 2x2 cores, twisted pairs, Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6, FM, CSA IS Cl.1 Div 1 Gr. A-D, ATEX, NEPSI II 3G Ex nL IIC, TIIS
Additional certifications
Also available as TÜV approved SIL version
Conductivity Specification
Measuring principle
Conductive
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug-head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against humidity
Material
Cable sheath: TPE, Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch), Cores: 2x2 cores, twisted pairs, Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6, FM, CSA IS Cl.1 Div 1 Gr. A-D, ATEX, NEPSI II 3G Ex nL IIC, TIIS
Additional certifications
Also available as TÜV approved SIL version
Oxygen Specification
Measuring principle
Amperometric oxygen measurement
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug-head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against humidity
Material
Cable sheath: TPE, Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch), Cores: 2x2 cores, twisted pairs, Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6, FM, CSA IS Cl.1 Div 1 Gr. A-D, ATEX, NEPSI II 3G Ex nL IIC, TIIS
Additional certifications
Also available as TÜV approved SIL version
Disinfection Specification
Measuring principle
Free chlorine
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against humidity
Material
Cable sheath: TPE, Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch), Cores: 2x2 cores, twisted pairs, Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Product Overview
The FM Series digital measure counters from Autonics are designed to provide precise and reliable counting capabilities. These counters can preset a multiple or divisor for each...
Tecpel Digital Thermometer Single Input - DTM-305
Non Differential Temperautre (T1-T2), Hand-Held lightweight design, Single Output
A thermometer measures the temperature of the environment...
Application
The Deltapilot FMB53, designed with a cable and mounting clamp, is ideal for use in environmental industries. It features the Contite measuring cell, making it suitable for level...
Application
The Waterpilot FMX11 transmitter is designed primarily for environmental applications, providing accurate hydrostatic level measurements. It is certified for use in drinking water...
Application
The Deltapilot FMB52, featuring a cable design with a fixed process connection, is equipped with a Contite measuring cell and is primarily utilized in the process and environmental...