Endress+Hauser
Combined pH/ORP Sensor Memosens CPS76E
- SKU:
- Memosens CPS76E Series
- MPN:
- Memosens CPS76E
- Weight:
- 0.00 Grams
Description
Application
The Memosens CPS76E is a robust solution for simultaneous pH and ORP measurement, designed to excel in challenging environments. Its specialized, contamination-resistant reference system ensures consistent performance even in contaminated or aggressive media and those with low conductivity. With Memosens 2.0 digital technology, the CPS76E offers superior process reliability and user-friendly operation. It is moisture-resistant, supports lab-based calibration, and provides enhanced storage for calibration and process data, forming a strong foundation for predictive maintenance. This sensor is ideal for chemical industry processes and monitoring applications where:
- pH or ORP values change rapidly
- There is a high concentration of electrode poisons like Hâ‚‚S
Certified for use in hazardous areas, the Memosens CPS76E comes with ATEX, IECEx, CSA C/US, NEPSI, Japan, and INMETRO approvals for zones 0, 1, and 2.
Benefits
Memosens 2.0 technology offers expanded data storage capabilities for calibration and process data, enabling better trend analysis and laying a future-proof foundation for predictive maintenance and enhanced IIoT services. It supports simultaneous measurement of pH, ORP, and rH values (in rH mode), delivering a more comprehensive process overview and enabling tighter process control. The sensor’s optional pressurized reference ensures accurate readings in challenging media, such as dispersions. A unique ion trap feature prevents contamination of the electrode junction and reference, significantly extending the sensor's lifespan. It offers flexible installation options, including the ability to be mounted upside-down. With non-contact, inductive signal transmission, the CPS76E maximizes process safety. Reduced operating costs are achieved through minimized process interruptions and an extended sensor lifespan.
Documents
You may want to read this product's catalog. If so, please click to view the Memosens CPS76E Series datasheet.SPECIFICATIONS
ORP/Redox Specification
Measuring principle | Sensor ORP / Redox |
Application | Process technology and monitoring of processes with: - Rapidly changing pH values - High levels of electrode poisons, such as H2S |
Characteristic | Digital pH/ORP electrode for chemical processes with an ion trap for poison-resistant reference |
Measuring range | ORP: –1 500 to 1 500 mV Application B: pH: 0 to 14 Application H: pH: 0 to 12 |
Measuring principle | Gel compact electrode with ceramic junction and ion trap for simultaneous measurement of pH, ORP, and rH value (in rH mode) |
Design | All shaft lengths with temperature sensor Advanced gel technology |
Material | Sensor shaft: Glass to suit process pH membrane glass: Type B, Type N Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360, and 425 mm (4.68, 8.77, 14.04, and 16.57 inch) |
Process temperature | Application B and H: 0 to 140 °C (32 to 284 °F) Version TB: 0 to 140 °C (32 to 284 °F) Version TU, TP (pressurized reference): 0 to 140 °C (32 to 284 °F) for sterilization only Maximum 100 °C (212 °F) in continuous operation due to increasing pressure drop at T > 100 °C (212 °F) |
Process pressure | Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute Application H: 0.8 to 7 bar (11.6 to 101.5 psi) absolute |
Temperature sensor | NTC 30k |
Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex, and INMETRO approvals for use in hazardous areas Zone 0, Zone 1, and Zone 2 |
Connection | Inductive, digital connection head with Memosens 2.0 technology |
Ingress protection | IP68 |
pH Specification
Measuring principle | Potentiometric |
Application | Process technology and monitoring of processes with: - Rapidly changing pH values - High levels of electrode poisons, such as H2S |
Characteristic | Digital pH/ORP electrode for chemical process with an ion trap for poison-resistant reference |
Measuring range | ORP: –1 500 to 1 500 mV Application B: pH 0 to 14 Application H: pH 0 to 12 |
Measuring principle | Gel compact electrode with ceramic junction and ion trap for simultaneous measurement of pH, ORP, and rH value (in rH mode) |
Design | All shaft lengths with temperature sensor Advanced gel technology |
Material | Sensor shaft: Glass to suit process pH membrane glass: Type B, Type N Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360, and 425 mm (4.68, 8.77, 14.04, and 16.57 inch) |
Process temperature | Application B and H: 0 to 140 °C (32 to 284 °F) Version TB: 0 to 140 °C (32 to 284 °F) Version TU, TP (pressurized reference): - 0 to 140 °C (32 to 284 °F) (sterilization only) - Maximum 100 °C (212 °F) in continuous operation due to increasing pressure drop at T > 100 °C (212 °F) |
Process pressure | Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute Application H: 0.8 to 7 bar (11.6 to 101.5 psi) absolute |
Temperature sensor | NTC 30k |
Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1, and Zone 2 |
Connection | Inductive, digital connection head with Memosens 2.0 technology |
Ingress protection | IP68 |