Autonics Temperature Transmitters Humidity Transmitters THD-D2-C
- SKU:
- THD-D2-C
- MPN:
- THD-D2-C
- Weight:
- 220.00 Grams
- Minimum Purchase:
- 1 unit
Description
The THD series temperature/humidity transducers have built-in temperature and humidity sensors and are capable of various outputs including DC 4-20 mA, 1-5 VDC, RS485 communication. The temperature sensors have a range of -19.9 to 60.0°C and the humidity sensors have a range of 0.0 to 99.9% RH. The THD series is available in room type, duct mount type, and wall mount types.
THD-D2-C from Autonics is a temperature and humidity transducer. It is an indoor room type with 24VDC as input and 4-20mA as output.
THD-D2-C from Autonics comes with the following features:
- Indoor wall and duct mounting type temp. and humidity transducer.
- It has a compact design.
- Various output modes:
DC 4-20mA, 1-5VDC, RS485 (MODBUS RTU). - Wide range of measurement:
19.9~60â—¦C/0.0~99% RH. - Communication speed: 115200bps.
Brand Information
“Autonics” is a leading provider of automation solutions from South Korea. They develop and manufacture a wide range of automation products that are marketed worldwide. Their core products include various sensors, controllers, and motion devices, measuring equipment, laser marking systems, connection equipment and more. Autonics products are trusted and adopted by engineers in various industrial applications and their technology is widely applied in day-to-day automation devices.
With 12 international offices in South Korea, China, Japan, India, Vietnam, Indonesia, Malaysia, Russia, Turkey, USA, Brazil, Mexico, Autonics is able to provide comprehensive automation solutions for their customers across the globe.
Data Sheet
To View Data Sheet Please Click HereAdditional Information
Display type: |
Non-indicating type. |
Power supply: |
24VDC ±10%. |
Power consumption: |
Max. 2.4W. |
Measuring input: |
Temp., humidity built-in sensor. |
Output: |
4-20mA DC. |
Measurement range: |
Temp.: -19.9~60â—¦C. 0~99%RH. |
Accuracy: |
Temp. 5-40◦C max. ±0.5◦C |
Accuracy: |
Humidity Max. ±3% RH at 30-70% RH (at 25-45◦C). |
Sampling: |
period Fixed 0.5s. |
Insulation resistance: |
Min 100MΩ (at 500 VDC mega) |
Dielectric strength: |
500 VAC 50/60 Hz/min. |
Noise strength: |
±0.3kVthe square wave noise (pulse width: 1us) by the noise simulator. |
vibration: |
Mechanical 0.75mm amplitude at freq. of 10-55Hz in each X, Y, Z directions for 1 hour. |
vibration: |
Malfunction 0.5mm amplitude at freq. of 10-55Hz in each X, Y, Z directions for 10 min. |
Shock: |
Mechanical 300m/s2 (30G) in X, Y, Z direction for 3 times. |
Shock: |
Malfunction 100m/s2 (10G) in X, Y, Z direction for 3 times. |
Protection: |
IP65. |
Ambient temp.: |
0-60â—¦C (at non-freezing status). |
Storage temp.: |
-20~60â—¦C at (non freezing status). |
Cable: |
4p, Ø4mm, length: 2m. |
Unit weight: |
160g. |