null
Datexel

Signal Converter Thermocouple, Output Analog - DAT2145

(No reviews yet) Write a Review
SKU:
DAT2145
Weight:
90.00 Grams
  • Datexel Signal Converter Thermocouple, Output Analog - DAT2145
  • Signal Converter Thermocouple, Output Analog - DAT2145

Description

Datexel Signal Converter Thermocouple, Output Analog - DAT2145

Zero and Span values configurable, Good accuracy, EMC compliant – CE mark - High Quality

The converter DAT 2145 is designed to provide on its output a voltage or current signal linear and proportional with the value of voltage generated from the thermocouple connected to its input.

The DAT 2145 doesn't execute the linearisation of the input signal; this feature allows to use the converter with acquisition systems with an internal linearisation software.

The user can program the input and output ranges by the proper DIP-switches available after opening the suitable door located on the side of device (see “Input range table” and “Output range table” sections).

The regulation of Zero and Span values is made by the ZERO and SPAN potentiometers located on the top of device.

It is housed in a plastic enclosure of 12.5 mm thickness suitable for DIN rail mounting in according to EN-50022 and EN-50035 standards.

The advantages and features for Datexel Signal Converter DAT2145

  • Input for thermocouples type K, J, R, S and T
  • Unit of measure configurable in °C or °F
  • Zero and Span values configurable by DIP-switches
  • Voltage or current “voltage linear” output
  • Good accuracy and performance stability
  • EMC compliant – CE mark
  • DIN rail mounting in compliance with EN-50022 and EN-50035

Input for Datexel Signal Converter DAT2145

  • Sensor type Thermocouple Type J, K, R, S and T
  • Zero programmability Programmable from -50 up to 50 °C or from - 58 up to 122 °F
  • Span programmability Thermocouple Type K: from 100 up to 1370 °C or from 210 up to 2500 °F
  1. Thermocouple type J: from 100 up to 900 °C or from 210 up to 1650 °F
  2. Thermocouple type R: from 700 up to 1760 °C or from 1200 up to 3200 °F
  3. Thermocouple type S: from 700 up to 1760 °C or from 1290 up to 3200 °F
  4. Thermocouple type T: from 100 up to 450 °C or from 210 up to 840 °F
  • Input impedance ≥ 10 MW
  • Line resistance influence 0.2 mV / W

Output Datexel Signal Converter DAT2145

  • Signal type Configurable:4 ÷ 20 mA, 0 ÷ 20 mA, 0÷10 V
  • Burnout condition Positive out of scale (> 20 mA or > 10 V)
  • Maximum output signal 30 mA or 18 Vdc
  • Load resistance (Rload) Current output: ≤ 500 W ; Voltage output: ≥ 5 KW
  • Response time (from 10 to 90 % of f.s.) 500 ms
  • Warm-up time 3 minutes

Performances

  • Calibration error > of ± 0.1 % of f.s. or 0.2 °C
  • Linearity error (*) ± 0.05 % of f.s.
  • Cold Junction Compensation ± 0.5 °C
  • Thermal drift 0.02 % of f.s./°C ( for Span > 300 °C / 500 °F )
  • Power supply voltage (**) 18 ÷ 30 Vdc
  • Current consumption Current output: 40 mA max.
  • Voltage output: 10 mA max.

Electromagnetic Compatibility (EMC)

  • ( for industrial environments ) Immunity: EN 61000-6-2; Emission : EN 61000-6-4
  • Operating temperature -20 ÷ 70 °C
  • Storage temperature -40 ÷ 85 °C
  • Relative humidity (not cond.) 0 ÷ 90%
  • Maximum Altitude 2000 m
  • Installation Indoor
  • Category of installation II
  • Pollution Degree 2
  • Weight approx. 90 g

Mechanical Specifications

  • Material Self-extinguish plastic
  • IP Code IP20
  • Wiring wires with diameter 0.8÷2.1 mm2 /AWG 14-18
  • Tightening Torque 0.8 N m
  • Mounting in compliance with DIN rail standard EN-50022 and EN-50035

 

Series Information

“P.D.S. SERIES”: temperature and signal transmitters The P.D.S. (programmable by dip-switches) series transmitters and converters

can accept on their input signals coming from 2 or 3 wires Pt100. Thermocouple and Strain Gauge sensors or Voltage and Current signals.

• Single and double channel 4÷20 mA two wires transmitters for Pt100 input without galvanic isolation (DAT2065, DAT2066)

• 4÷20 mA two wires transmitter for Thermocouple input without galvanic isolation (DAT2045)

• Single and double channel converters for Pt100 input with configurable output as voltage or current without galvanic isolation (DAT2165, DAT2166)

• Isolated converter for Pt100 input with configurable output as voltage or current (DAT2061)

• Converter for Thermocouple input with configurable output as voltage or current without galvanic isolation (DAT2145)

• Isolated signal converters with configurable input and output as voltage or current (DAT5020. DAT5021, DAT5023I, DAT5023V)

• Isolated signal splitter with configurable input and output as voltage or current (DAT5022)

• Isolated signal converter for Strain Gauge input with configurable output as voltage or current (DAT5025) and converters for DIN rail mounting.

About Datexel:

Founded in 1992 from the commitment and aspiration of several partners as a small provincial company, through the years DATEXEL has become an established reality on Italian and international markets as a manufacturer of electronic equipment for industrial automation and control process.

The range of DATEXEL products includes: Transmitters, signal and temperature Converters (both analogue and digital), galvanic Isolators, signal Splitters, I/O Modules, Trip Amplifiers, Power Supply Units, current loop Isolators, analogue and digital Displays.

Documents

To View Data Sheet Datexel Signal Converter Thermocouple, Output Analog - DAT2145 Please Click Here
View AllClose

Warranty Information

One Year Warranty
View AllClose

Additional Information

Input:
TIONS (Typical @ 25 °C and in nominal conditions) Input Sensor type Thermocouple type J, K, R, S and T
Output:
Configurable:4 ÷ 20 mA, 0 ÷ 20 mA, 0÷10 V
Operative temperature:
-4℉ to 158℉ -20℃ to 70℃
Storage temperature:
-40℉ to 185℉ -40℃ to 85℃
Humidity (not condensed):
0 to 90 %
Maximum Altitude:
6500ft 2000m
Installation:
Indoor
Category of installation:
II
Weight:
90 g
Material:
Self-extinguish plastic
IP Rating:
IP20
Wiring size:
AWG 14-18 0.8÷2.1 mm²
Screw torque:
0.8 N m
Mounting:
DIN rail standard EN-50022 and EN-50035
Dimensions:
H 3.5" L 4.4" T 0.5" H 90 mm L 112 mm T 12.5 mm
EMC:
Immunity EN 61000-6-2, Emission EN 61000-6-4
View AllClose